SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:research.chalmers.se:3c41adc7-4a13-467c-92e2-7d42bf6c74a6"
 

Sökning: id:"swepub:oai:research.chalmers.se:3c41adc7-4a13-467c-92e2-7d42bf6c74a6" > Development of a Ti...

Development of a Time Domain Microwave System for Medical Diagnostics

Zeng, Xuezhi, 1980 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Fhager, Andreas, 1976 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
He, Zhongxia Simon, 1984 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa fler...
Persson, Mikael, 1959 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Linner, Peter, 1945 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Zirath, Herbert, 1955 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa färre...
 (creator_code:org_t)
2014
2014
Engelska.
Ingår i: IEEE Transactions on Instrumentation and Measurement. - 1557-9662 .- 0018-9456. ; 63:12, s. 2931-2939
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In this paper, a time-domain system dedicated to medical diagnostics has been designed, a prototype has been built and its performance has been evaluated. Measurements show that the system has a 3-dB bandwith of about 3.5 GHz and a signal to noise ratio over 40 dB in the frequency range about 800 MHz to 3.8 GHz. The system has been used to perform a microwave tomographic image reconstruction test. The same target was reconstructed based on data measured with a network analyzer. A comparison between the images shows very small differences, and proves the functionality of the time domain system.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Annan elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Other Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Nyckelord

Microwave imaging
time domain measurements
ultrawideband (UWB)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy