Search: id:"swepub:oai:research.chalmers.se:3d493952-f01c-4460-8557-287643af0086" >
Hit detection in se...
Hit detection in serial femtosecond crystallography using X-ray spectroscopy of plasma emission
-
- Jonsson, H. O. (author)
- Uppsala universitet,Uppsala University
-
- Caleman, C. (author)
- Uppsala universitet,Uppsala University,Deutsches Elektronen-Synchrotron (DESY)
-
- Andreasson, Jakob, 1975 (author)
- Chalmers tekniska högskola,Chalmers University of Technology
-
show more...
-
- Timneanu, N. (author)
- Uppsala universitet,Uppsala University
-
show less...
-
(creator_code:org_t)
- 2017-10-13
- 2017
- English.
-
In: IUCrJ. - : International Union of Crystallography (IUCr). - 2052-2525. ; 4, s. 778-784
- Related links:
-
http://publications.... (primary) (free)
-
show more...
-
https://journals.iuc...
-
https://doi.org/10.1...
-
https://research.cha...
-
show less...
Abstract
Subject headings
Close
- Serial femtosecond crystallography is an emerging and promising method for determining protein structures, making use of the ultrafast and bright X-ray pulses from X-ray free-electron lasers. The upcoming X-ray laser sources will produce well above 1000 pulses per second and will pose a new challenge: how to quickly determine successful crystal hits and avoid a high-rate data deluge. Proposed here is a hit-finding scheme based on detecting photons from plasma emission after the sample has been intercepted by the X-ray laser. Plasma emission spectra are simulated for systems exposed to high-intensity femtosecond pulses, for both protein crystals and the liquid carrier systems that are used for sample delivery. The thermal radiation from the glowing plasma gives a strong background in the XUV region that depends on the intensity of the pulse, around the emission lines from light elements (carbon, nitrogen, oxygen). Sample hits can be reliably distinguished from the carrier liquid based on the characteristic emission lines from heavier elements present only in the sample, such as sulfur. For buffer systems with sulfur present, selenomethionine substitution is suggested, where the selenium emission lines could be used both as an indication of a hit and as an aid in phasing and structural reconstruction of the protein.
Subject headings
- NATURVETENSKAP -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
- NATURAL SCIENCES -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)
Keyword
- serial femtosecond crystallography
- hit detection
- protein structure
- plasma emission spectra
Publication and Content Type
- art (subject category)
- ref (subject category)
Find in a library
-
IUCrJ
(Search for host publication in LIBRIS)
To the university's database