SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:research.chalmers.se:c6279571-7a53-4820-aa07-067751c4c233"
 

Sökning: id:"swepub:oai:research.chalmers.se:c6279571-7a53-4820-aa07-067751c4c233" > Experimental determ...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00002750naa a2200277 4500
001oai:research.chalmers.se:c6279571-7a53-4820-aa07-067751c4c233
003SwePub
008171008s2017 | |||||||||||000 ||eng|
024a https://doi.org/10.1109/APEC.2017.79308772 DOI
024a https://research.chalmers.se/publication/2501082 URI
040 a (SwePub)cth
041 a engb eng
042 9 SwePub
072 7a kon2 swepub-publicationtype
072 7a ref2 swepub-contenttype
100a Andersson, A.u Volvo Cars4 aut
2451 0a Experimental determination of inverter losses and sound consequences of using DPWM in an HEV
264 1c 2017
520 a This paper presents an experimental determination of the inverter losses and acoustic noise consequences of using discontinuous PWM in a hybrid/electric vehicle application. Acoustic noise and stator vibrations were evaluated using measurements and inverter losses were evaluated both with the use of measurements as well as simulations. The entire operational area for positive torque was covered in the analysis. The results show that the total inverter losses were decreased with about 10-20% when DPWM was used. The introduction of discontinuity in the voltage modulation affects the harmonic content of the phase current. This was further investigated, both electrically and acoustically, focusing on harmonics around the switching frequency, since these are acoustically challenging in the intended application. Measurements show that the magnitude of phase current harmonics around the switching frequency were increased when discontinuous PWM was used. This increase, in the magnitude of these phase current harmonics, amplifies the corresponding harmonics in the stator vibrations which also increased the associated acoustic noise. Therefore, the acoustic noise radiated from the machine and the inverter was enlarged when discontinuous PWM was used. However, the results also show that the adverse acoustic effects were significantly decreased as the machine was operated in the field weakening area.
650 7a TEKNIK OCH TEKNOLOGIERx Elektroteknik och elektronik0 (SwePub)2022 hsv//swe
650 7a ENGINEERING AND TECHNOLOGYx Electrical Engineering, Electronic Engineering, Information Engineering0 (SwePub)2022 hsv//eng
700a Thiringer, Torbjörn,d 1966u Chalmers tekniska högskola,Chalmers University of Technology4 aut0 (Swepub:cth)thorbear
710a Volvo Carsb Chalmers tekniska högskola4 org
773t Conference Proceedings - IEEE Applied Power Electronics Conference and Exposition - APECg , s. 1382-1388q <1382-1388
8564 8u https://doi.org/10.1109/APEC.2017.7930877
8564 8u https://research.chalmers.se/publication/250108

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Andersson, A.
Thiringer, Torbj ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Elektroteknik oc ...
Artiklar i publikationen
Av lärosätet
Chalmers tekniska högskola

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy