SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:kth-12208"
 

Search: onr:"swepub:oai:DiVA.org:kth-12208" > A packaged optical ...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00003369naa a2200553 4500
001oai:DiVA.org:kth-12208
003SwePub
008100325s2010 | |||||||||||000 ||eng|
024a https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-122082 URI
024a https://doi.org/10.1039/b914183a2 DOI
040 a (SwePub)kth
041 a engb eng
042 9 SwePub
072 7a ref2 swepub-contenttype
072 7a art2 swepub-publicationtype
100a Carlborg, Carl Fredriku KTH,Mikrosystemteknik4 aut0 (Swepub:kth)u1mghzhj
2451 0a A packaged optical slot-waveguide ring resonator sensor array for multiplex label-free assays in labs-on-chips
264 c 2010
264 1b Royal Society of Chemistry (RSC),c 2010
338 a electronic2 rdacarrier
500 a QC 20100715
520 a We present the design, fabrication, and characterisation of an array of optical slot-waveguide ring resonator sensors, integrated with microfluidic sample handling in a compact cartridge, for multiplexed real-time label-free biosensing. Multiplexing not only enables high throughput, but also provides reference channels for drift compensation and control experiments. Our use of alignment tolerant surface gratings to couple light into the optical chip enables quick replacement of cartridges in the read-out instrument. Furthermore, our novel use of a dual surface-energy adhesive film to bond a hard plastic shell directly to the PDMS microfluidic network allows for fast and leak-tight assembly of compact cartridges with tightly spaced fluidic interconnects. The high sensitivity of the slot-waveguide resonators, combined with on-chip referencing and physical modelling, yields a volume refractive index detection limit of 5 x 10(-6) refractive index units (RIUs) and a surface mass density detection limit of 0.9 pg mm(-2), to our knowledge the best reported values for integrated planar ring resonators.
653 a MICRORING RESONATOR
653 a SILICON
653 a INTERFACE
653 a BIOSENSOR
653 a SYSTEMS
653 a TECHNOLOGY
653 a TEKNIKVETENSKAP
700a Gylfason, Kristinn Björgvinu KTH,Mikrosystemteknik4 aut0 (Swepub:kth)u1v3y7u7
700a Kazmierczak, Andrzej4 aut
700a Dortu, Fabian4 aut
700a Banuls Polo, Maria Jose4 aut
700a Maquieira Catala, Angel4 aut
700a Kresbach, Gerhard4 aut
700a Sohlström, Hansu KTH,Mikrosystemteknik4 aut0 (Swepub:kth)u1b1nduy
700a Moh, Thomasu KTH,Mikrosystemteknik4 aut0 (Swepub:kth)-
700a Vivien, Laurent4 aut
700a Popplewell, Jon4 aut
700a Ronan, Gerry4 aut
700a Barrios, Carlos Angulo4 aut
700a Stemme, Göranu KTH,Mikrosystemteknik4 aut0 (Swepub:kth)u1oyebfq
700a van der Wijngaart, Wouteru KTH,Mikrosystemteknik4 aut0 (Swepub:kth)u1wdbont
710a KTHb Mikrosystemteknik4 org
773t Lab on a Chipd : Royal Society of Chemistry (RSC)g 10:3, s. 281-290q 10:3<281-290x 1473-0197x 1473-0189
856u https://kth.diva-portal.org/smash/get/diva2:305946/FULLTEXT01.pdfx primaryx Raw objecty fulltext:print
856u http://kth.diva-portal.org/smash/get/diva2:305946/FULLTEXT01
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-12208
8564 8u https://doi.org/10.1039/b914183a

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view