Ultrasound speckle tracking for radial, longitudinal and circumferential strain estimation of the carotid artery : An in vitro validation via sonomicrometry using clinical and high-frequency ultrasound

Larsson, Matilda (författare)
KTH,Medicinsk bildteknik,KU Leuven, Campus Gasthuisberg OandN1, Belgium
Heyde, Brecht (författare)
Kremer, Florence (författare)
visa fler...
Brodin, Lars-Ake (författare)
KTH,Medicinsk bildteknik
D'hooge, Jan (författare)
visa färre...
 (creator_code:org_t)
Elsevier BV, 2014
2014
Engelska.
Ingår i: Ultrasonics. - : Elsevier BV. - 0041-624X .- 1874-9968. ; 56, s. 399-408
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Ultrasound speckle tracking for carotid strain assessment has in the past decade gained interest in studies of arterial stiffness and cardiovascular diseases. The aim of this study was to validate and directly contrast carotid strain assessment by speckle tracking applied on clinical and high-frequency ultrasound images in vitro. Four polyvinyl alcohol phantoms mimicking the carotid artery were constructed with different mechanical properties and connected to a pump generating carotid flow profiles. Gray-scale ultrasound long-and short-axis images of the phantoms were obtained using a standard clinical ultrasound system, Vivid 7 (GE Healthcare, Horten, Norway) and a high-frequency ultrasound system, Vevo 2100 (FUJIFILM, VisualSonics, Toronto, Canada) with linear-array transducers (12L / MS250). Radial, longitudinal and circumferential strains were estimated using an in-house speckle tracking algorithm and compared with reference strain acquired by sonomicrometry. Overall, the estimated strain corresponded well with the reference strain. The correlation between estimated peak strain in clinical ultrasound images and reference strain was 0.91 (p < 0.001) for radial strain, 0.73 (p < 0.001) for longitudinal strain and 0.90 (p < 0.001) for circumferential strain and for high-frequency ultrasound images 0.95 (p < 0.001) for radial strain, 0.93 (p < 0.001) for longitudinal strain and 0.90 (p < 0.001) for circumferential strain. A significant larger bias and root mean square error was found for circumferential strain estimation on clinical ultrasound images compared to high frequency ultrasound images, but no significant difference in bias and root mean square error was found for radial and longitudinal strain when comparing estimation on clinical and high-frequency ultrasound images. The agreement between sonomicrometry and speckle tracking demonstrates that carotid strain assessment by ultrasound speckle tracking is feasible.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Ultrasound speckle tracking
Carotid strain
Vessel phantom
High-frequency ultrasound
Sonomicrometry

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Larsson, Matilda
Heyde, Brecht
Kremer, Florence
Brodin, Lars-Ake
D'hooge, Jan
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Ultrasonics
Av lärosätet
Kungliga Tekniska Högskolan

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy