SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:kth-327900"
 

Search: onr:"swepub:oai:DiVA.org:kth-327900" > Addressing the Dete...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Addressing the Detection of Ammonium Ion in Environmental Water Samples via Tandem Potentiometry-Ion Chromatography

Gil, R. L. (author)
Amorim, C. G. (author)
Cuartero, Maria, PhD, 1984- (author)
KTH,Tillämpad fysikalisk kemi
 (creator_code:org_t)
2022-01-20
2022
English.
In: ACS Measurement Science Au. - : American Chemical Society (ACS). - 2694-250X. ; 2:3, s. 199-207
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • An analytical methodology for detecting ammonium ion (NH4+) in environmental water through potentiometry-ion chromatography (IC) in tandem is presented here. A multielectrode flow cell is implemented as a potentiometric detector after chromatographic separation of cations in the sample. The electrodes are fabricated via miniaturized all-solid-state configuration, using a nonactin-based plasticized polymeric membrane as the sensing element. The overall analytical setup is based on an injection valve, column, traditional conductometric detector, and new potentiometric detector (in that order), permitting the characterization of the analytical performance of the potentiometric detector while validating the results. The limit of detection was found to be ca. 3 × 10-7 M NH4+ concentration after linearization of the potentiometric response, and intra- and interelectrode variations of <10% were observed. Importantly, interference from other cations was suppressed in the tandem potentiometry-IC, and thus, the NH4+ content in fresh- and seawater samples from different locations was successfully analyzed. This analytical technology demonstrated a great potential for the reliable monitoring of NH4+ at micromolar levels, in contrast to the conductivity detector and previously reported NH4+ potentiometric sensors functioning in batch mode or even coupled with IC. Additionally, the suitability of the potentiometric cell for selective multi-ion analysis in the same sample, i.e., Na+, NH4+, and K+ in water, has been proven.

Subject headings

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Keyword

ammonium
environmental water samples
ion chromatography
ion-selective electrodes
potentiometry
tandem analytical technique

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Gil, R. L.
Amorim, C. G.
Cuartero, Maria, ...
About the subject
NATURAL SCIENCES
NATURAL SCIENCES
and Chemical Science ...
and Analytical Chemi ...
Articles in the publication
ACS Measurement ...
By the university
Royal Institute of Technology

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view