SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:liu-21206"
 

Search: onr:"swepub:oai:DiVA.org:liu-21206" > Deng X > Standardized evalua...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00005811naa a2200721 4500
001oai:DiVA.org:liu-21206
003SwePub
008090930s2009 | |||||||||||000 ||eng|
009oai:DiVA.org:kth-258836
024a https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-212062 URI
024a https://doi.org/10.1016/j.media.2009.06.0032 DOI
024a https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-2588362 URI
040 a (SwePub)liud (SwePub)kth
041 a engb eng
042 9 SwePub
072 7a ref2 swepub-contenttype
072 7a art2 swepub-publicationtype
100a Schaap, M.u Biomedical Imaging Group Rotterdam, The Netherlands4 aut
2451 0a Standardized evaluation methodology and reference database for evaluating coronary artery centerline extraction algorithms
264 1b Elsevier,c 2009
338 a print2 rdacarrier
500 a QC 20190913
520 a Efficiently obtaining a reliable coronary artery centerline from computed tomography angiography data is relevant in clinical practice. Whereas numerous methods have been presented for this purpose, up to now no standardized evaluation methodology has been published to reliably evaluate and compare the performance of the existing or newly developed coronary artery centerline extraction algorithms. This paper describes a standardized evaluation methodology and reference database for the quantitative evaluation of coronary artery centerline extraction algorithms. The contribution of this work is fourfold: (1) a method is described to create a consensus centerline with multiple observers, (2) well-defined measures are presented for the evaluation of coronary artery centerline extraction algorithms, (3) a database containing 32 cardiac CTA datasets with corresponding reference standard is described and made available, and (4) 13 coronary artery centerline extraction algorithms, implemented by different research groups, are quantitatively evaluated and compared. The presented evaluation framework is made available to the medical imaging community for benchmarking existing or newly developed coronary centerline extraction algorithms.
650 7a TEKNIK OCH TEKNOLOGIERx Medicinteknikx Medicinsk bildbehandling0 (SwePub)206032 hsv//swe
650 7a ENGINEERING AND TECHNOLOGYx Medical Engineeringx Medical Image Processing0 (SwePub)206032 hsv//eng
653 a Centerline extraction; Computed tomography; Coronaries; Standardized evaluation; Tracking
653 a MEDICINE
653 a MEDICIN
700a Metz, C.T.u Biomedical Imaging Group Rotterdam, The Netherlands,Universidad Politécnica de Madrid, Spain4 aut
700a van Walsum, T.u Biomedical Imaging Group Rotterdam, The Netherlands4 aut
700a van der Giessen, A.G.u Biomedical Imaging Group Rotterdam, The Netherlands4 aut
700a Weustink, A.C.u Erasmus MC, Rotterdam, The Netherlands4 aut
700a Mollet, N.R.u Erasmus MC, Rotterdam, The Netherlands4 aut
700a Bauer, C.u Graz University of Technology, Austria4 aut
700a Bogunovic, H.u Center for Computational Imaging and Simulation Technologies in Biomedicine (CISTIB), Barcelona, Spain4 aut
700a Castro, C.u Universidad Politécnica de Madrid, Spain,MeVis Research, Bremen, Germany4 aut
700a Deng, X.u Siemens Corporate Research, Princeton, NJ, USA4 aut
700a Dikici, E.u University of Florida College of Medicine, Jacksonville, FL, USA4 aut
700a O'Donnell, T.u Siemens Corporate Research, Princeton, NJ, USA4 aut
700a Frenay, M.u Leiden University Medical Center, The Netherlands4 aut
700a Friman, O.u MeVis Research, Bremen, Germany4 aut
700a Hoyos, M.H.u Universidad de los Andes, Bogota, Colombia4 aut
700a Kitslaar, P.H.u Leiden University Medical Center, The Netherlands4 aut
700a Krissian, K.u University of Las Palmas of Gran Canaria, Spain,Childrens Hospital Boston, MA, USA4 aut
700a Kuhnel, C.u MeVis Research, Bremen, Germany4 aut
700a Luengo-Oroz, M.A.u Universidad Politécnica de Madrid, Spain4 aut
700a Orkisz, M.u Université de Lyon, France4 aut
700a Smedby, Örjanu Östergötlands Läns Landsting,Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk radiologi,Hälsouniversitetet,Röntgenkliniken i Linköping4 aut0 (Swepub:liu)orjsm14
700a Styner, M.u University of North Carolina, Chapel Hill, NC, USA4 aut
700a Szymczak, A.u Colorado School of Mines, Golden, CO, USA4 aut
700a Tek, H.u Siemens Corporate Research, Princeton, NJ, USA4 aut
700a Wang, Chunliangu Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk radiologi,Hälsouniversitetet,Linköping Univ., Linköping, Sweden4 aut0 (Swepub:kth)u1tbkeej
700a Warfield, S.K.u Childrens Hospital Boston, MA, USA4 aut
700a Zambal, S.u VRVis Research Center for Virtual Reality and Visualization, Vienna, Austria4 aut
700a Zhang, Y.u The Methodist Hospital Research Institute, Houston, TX, USA4 aut
700a Krestin, G.P.u Erasmus MC, Rotterdam, The Netherlands4 aut
700a Niessen, W.J.u Erasmus MC, Rotterdam, The Netherlands4 aut
710a Biomedical Imaging Group Rotterdam, The Netherlandsb Universidad Politécnica de Madrid, Spain4 org
773t Medical Image Analysisd : Elsevierg 13:5, s. 701-714q 13:5<701-714x 1361-8415x 1361-8423
856u https://cdr.lib.unc.edu/downloads/cn69mc016
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-21206
8564 8u https://doi.org/10.1016/j.media.2009.06.003
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-258836

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view