SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:liu-95876"
 

Sökning: onr:"swepub:oai:DiVA.org:liu-95876" > Standardized evalua...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00006544naa a2200805 4500
001oai:DiVA.org:liu-95876
003SwePub
008130805s2013 | |||||||||||000 ||eng|
009oai:DiVA.org:kth-258850
024a https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-958762 URI
024a https://doi.org/10.1016/j.media.2013.05.0072 DOI
024a https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-2588502 URI
040 a (SwePub)liud (SwePub)kth
041 a engb eng
042 9 SwePub
072 7a ref2 swepub-contenttype
072 7a art2 swepub-publicationtype
100a Kirişli, Hortenseu Erasmus MC, Rotterdam, The Netherlands,Biomedical Imaging Group Rotterdam4 aut
2451 0a Standardized evaluation framework for evaluating coronary artery stenosis detection, stenosis quantification and lumen segmentation algorithms in computed tomography angiography
264 1b Elsevier,c 2013
338 a print2 rdacarrier
500 a QC 20191025
520 a Though conventional coronary angiography (CCA) has been the standard of reference for diagnosing coronary artery disease in the past decades, computed tomography angiography (CIA) has rapidly emerged, and is nowadays widely used in clinical practice. Here, we introduce a standardized evaluation framework to reliably evaluate and compare the performance of the algorithms devised to detect and quantify the coronary artery stenoses, and to segment the coronary artery lumen in CIA data. The objective of this evaluation framework is to demonstrate the feasibility of dedicated algorithms to: (I) (semi-)automatically detect and quantify stenosis on CIA, in comparison with quantitative coronary angiography (QCA) and CIA consensus reading, and (2) (semi-)automatically segment the coronary lumen on CIA, in comparison with expert's manual annotation. A database consisting of 48 multicenter multivendor cardiac CIA datasets with corresponding reference standards are described and made available. The algorithms from 11 research groups were quantitatively evaluated and compared. The results show that (1) some of the current stenosis detection/quantification algorithms may be used for triage or as a second-reader in clinical practice, and that (2) automatic lumen segmentation is possible with a precision similar to that obtained by experts. The framework is open for new submissions through the website, at http://coronary.bigr.nl/stenoses/.
650 7a TEKNIK OCH TEKNOLOGIERx Medicinteknikx Medicinsk bildbehandling0 (SwePub)206032 hsv//swe
650 7a ENGINEERING AND TECHNOLOGYx Medical Engineeringx Medical Image Processing0 (SwePub)206032 hsv//eng
653 a Standardized evaluation framework; Coronary arteries; Computed tomography angiography (CTA); stenoses detection; stenoses quantification
700a Schaap, M.u Erasmus MC, Rotterdam, The Netherlands,Toshiba Medical Visualization Systems, Edinburgh, UK4 aut
700a Metz, C. T.u Erasmus MC, Rotterdam, The Netherlands4 aut
700a Dharampal, A. S.u Erasmus MC, Rotterdam, The Netherlands4 aut
700a Meijboom, W. B.u Erasmus MC, Rotterdam, The Netherlands4 aut
700a Papadopoulou, S. L.u Erasmus MC, Rotterdam, The Netherlands4 aut
700a Dedic, A.u Erasmus MC, Rotterdam, The Netherlands4 aut
700a Nieman, K.u Erasmus MC, Rotterdam, The Netherlands4 aut
700a de Graaf, M. A.u Leiden UMC, The Netherlands4 aut
700a Meijs, M. F. L.u UMC Utrecht, The Netherlands4 aut
700a Cramer, M. J.u UMC Utrecht, The Netherlands4 aut
700a Broersen, A.u Leiden UMC, The Netherlands4 aut
700a Cetin, S.u SabancıUniversity, Turkey4 aut
700a Eslami, A.u Technical University of Munich, Germany4 aut
700a Flórez-Valencia, L.u Pontificia Universidad Javeriana, Bogotá, Colombia4 aut
700a Lor, K.L.u National Taiwan University, Taipei, Taiwan4 aut
700a Matuszewski, B.u University of Central Lancashire, Preston, UK4 aut
700a Melki, I.u Université Paris-Est, France4 aut
700a Mohr, B.u Toshiba Medical Visualization Systems, Edinburgh, UK4 aut
700a Öksüz, I.u Bahçeşehir University, Istanbul, Turkey4 aut
700a Shahzad, R.u Erasmus MC, Rotterdam The Netherlands4 aut
700a Wang, Chunliangu Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Avdelningen för radiologiska vetenskaper,Hälsouniversitetet,Center for Medical Imaging Science and Visualization, Dept.of Medical and Health Sciences, Linköping University, Linköping4 aut0 (Swepub:kth)u1tbkeej
700a Kitslaar, P. H.u Leiden UMC, The Netherlands4 aut
700a Unal, G.u Sabancı University, Turkey4 aut
700a Katouzian, A.u Technical University of Munich, Germany4 aut
700a Orkisz, M.u Université de Lyon, France4 aut
700a Chen, C.M.u National Taiwan University, Taipei, Taiwan4 aut
700a Precioso, F.u University Nice-Sophia Antipolis, France4 aut
700a Najman, L.u Université Paris-Est, France4 aut
700a Masood, S.u Toshiba Medical Visualization Systems, Edinburgh, UK4 aut
700a Ünay, D.u Bahçeşehir University, Istanbul, Turkey4 aut
700a van Vliet, L.u Delft University of Technology, The Netherlands4 aut
700a Moreno, Rodrigo,d 1973-u Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Avdelningen för radiologiska vetenskaper,Hälsouniversitetet4 aut0 (Swepub:liu)rodmo29
700a Goldenberg, R.u Rcadia Medical Imaging, Haïfa, Israel4 aut
700a Vuçini, E.u VRVis Research Center for Virtual Reality and Visualization, Vienna, Austria4 aut
700a Krestin, G. P.u Erasmus MC, Rotterdam, The Netherlands4 aut
700a Niessen, W. J.u Erasmus MC, Rotterdam, The Netherlands4 aut
700a van Walsum, T.u Erasmus MC, Rotterdam, The Netherlands4 aut
700a Kiri\csli, H A4 aut
710a Erasmus MC, Rotterdam, The Netherlandsb Biomedical Imaging Group Rotterdam4 org
773t Medical Image Analysisd : Elsevierg 17:8, s. 859-876q 17:8<859-876x 1361-8415x 1361-8423
856u https://hal.archives-ouvertes.fr/hal-00874107/file/hkirisli_MedIA_Challenge_R2.pdf
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-95876
8564 8u https://doi.org/10.1016/j.media.2013.05.007
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-258850

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy