100a Thunberg, Per,d 1968-u Department of Medical Physics, Örebro University Hospital, Örebro, Sweden4 aut0 (Swepub:oru)prtg
2451 0a Flow and peak velocity measurements in patients with aortic valve stenosis using phase contrast MR accelerated with k-t BLAST
264 1a Clare, Ireland :b Elsevier,c 2012
338 a print2 rdacarrier
500 a Funding agency:Research Committee of Örebro County Council 
520 a Objective: To investigate the accuracy of velocity measurements in patients with aortic valve stenosis using phase contrast (PC) imaging accelerated with SENSE (Sensitivity Encoding) and k-t BLAST (Broad-use Linear Acquisition Speed-up Technique).Methods: Accelerated quantitative breath hold PC measurements, using SENSE and k-t BLAST, were performed in twelve patients whose aortic valve stenosis had been initially diagnosed using echocardiography. Stroke volume (SV) and peak velocity measurements were performed on each subject in three adjacent slices using both accelerating methods.Results: The peak velocities measured with PC MRI using SENSE were -8.0±9.5% lower (p<0.01) compared to the peak velocities measured with k-t BLAST and the correlation was r=0.83. The stroke volumes when using SENSE were slightly higher 0.4±17.1 ml compared to the SV obtained using k-t BLAST but the difference was not significant (p>0.05).Conclusions In this study higher peak velocities were measured in patients with aortic stenosis when combining k-t BLAST with PC MRI compared to PC MRI using SENSE. A probable explanation of this difference is the higher temporal resolution achieved in the k-t BLAST measurement. There was, however, no significant difference between calculated SV based on PC MRI using SENSE and k-t BLAST, respectively.
650 7a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Radiologi och bildbehandling0 (SwePub)302082 hsv//swe
650 7a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Radiology, Nuclear Medicine and Medical Imaging0 (SwePub)302082 hsv//eng
653 a Aortic valve
653 a stenosis
653 a k-t BLAST
653 a SENSE
653 a phase contrast imaging
653 a Radiologi
653 a Radiology
700a Emilsson, Kent,d 1963-u Department of Clinical Physiology, Örebro University Hospital, Örebro, Sweden4 aut0 (Swepub:oru)kten
700a Rask, Peteru Department of Clinical Physiology, Örebro University Hospital, Örebro, Sweden4 aut0 (Swepub:oru)prk
700a Kähäri, Andersu Department of Radiology, Örebro University Hospital, Örebro, Sweden4 aut
710a Department of Medical Physics, Örebro University Hospital, Örebro, Swedenb Department of Clinical Physiology, Örebro University Hospital, Örebro, Sweden4 org
773t European Journal of Radiologyd Clare, Ireland : Elsevierg 81:9, s. 2203-2207q 81:9<2203-2207x 0720-048Xx 1872-7727
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:oru:diva-27174
8564 8u https://doi.org/10.1016/j.ejrad.2011.06.034

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Thunberg, Per, 1 ...
Emilsson, Kent, ...
Rask, Peter
Kähäri, Anders
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
European Journal ...
Av lärosätet
Örebro universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy