SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:oru-5167"
 

Sökning: onr:"swepub:oai:DiVA.org:oru-5167" > Accuracy and precis...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00003356naa a2200385 4500
001oai:DiVA.org:oru-5167
003SwePub
008090129s2009 | |||||||||||000 ||eng|
024a https://urn.kb.se/resolve?urn=urn:nbn:se:oru:diva-51672 URI
024a https://doi.org/10.1016/j.chroma.2008.10.0912 DOI
040 a (SwePub)oru
041 a engb eng
042 9 SwePub
072 7a ref2 swepub-contenttype
072 7a art2 swepub-publicationtype
100a Lindström, Gunillau Örebro universitet,Akademin för naturvetenskap och teknik,MTM Miljö och Hälsa4 aut0 (Swepub:oru)glm
2451 0a Accuracy and precision in the determination of perfluorinated chemicals in human blood verified by interlaboratory comparisons
264 1b Elsevier,c 2009
338 a electronic2 rdacarrier
520 a Perfluorinated chemicals, PFCs, are analyzed in laboratories worldwide to determine human blood levels and exposure pathways. The development of the  nalytical echnique has been rapid in the last ten years, and prerequisites for accurate and precise determination of PFCs in human blood at low ng/g concentrations are today readily available. The main contributing factors are the improved LC-MS instrumentations, the increased availability of native and mass labeled PFC standards, and new column materials available for chromatographic separations. The results of the first international interlaboratory study (ILS) in 2005 on PFCs revealed relatively better analytical results for human blood analyses when compared to analyses of a number of environmental matrices. The representative accuracy for the analyses of PFCs in human matrixes reported in recent years was established in the second human serum ILS in 2006. Interlaboratory standard deviations for the two human serum samples one low level concentration and one medium level concentration were found to be 12% and 16% for PFOS, respectively, and 47% and 21% for PFOA, respectively. Reported detections for all PFCs followed a frequency of PFOS>PFOA>PFHxS>PFNA>PFDA>>PFDoA>> PFDS>>PFHxA. Due to the small number of reported values for the other perfluorosulfonates and perfluorocarboxylates, standard deviations were not established. 
650 7a NATURVETENSKAPx Kemix Analytisk kemi0 (SwePub)104012 hsv//swe
650 7a NATURAL SCIENCESx Chemical Sciencesx Analytical Chemistry0 (SwePub)104012 hsv//eng
653 a perfluorinated chemicals PFOS PFOA QA-QC
653 a Analytical chemistry
653 a Analytisk kemi
653 a Chemistry
653 a Kemi
700a Kärrman, Annau Örebro universitet,Akademin för naturvetenskap och teknik,MTM Miljö och Hälsa4 aut0 (Swepub:oru)ankn
700a van Bavel, Bertu Örebro universitet,Akademin för naturvetenskap och teknik,MTM Miljö och Hälsa4 aut0 (Swepub:oru)bvl
710a Örebro universitetb Akademin för naturvetenskap och teknik4 org
773t Journal of Chromatography Ad : Elsevierg 1216:3, s. 394-400q 1216:3<394-400x 0021-9673x 1873-3778
856u https://oru.diva-portal.org/smash/get/diva2:158082/FULLTEXT01.pdfx primaryx Raw objecty fulltext:preprint
856u http://oru.diva-portal.org/smash/get/diva2:158082/FULLTEXT01
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:oru:diva-5167
8564 8u https://doi.org/10.1016/j.chroma.2008.10.091

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Lindström, Gunil ...
Kärrman, Anna
van Bavel, Bert
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Kemi
och Analytisk kemi
Artiklar i publikationen
Journal of Chrom ...
Av lärosätet
Örebro universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy