100 | 1 | a Andersson, Bengt Olofu RISE,SP – Sveriges Tekniska Forskningsinstitut4 aut |
245 | 1 0 | a The reference step method for DC voltage at 1 mV and 10 mV |
264 | 1 | b Institute of Electrical and Electronics Engineers Inc.c 2014 |
338 | a print2 rdacarrier | |
520 | a We have investigated the performance of a method called the Reference Step Method at low voltage levels. The method has been evaluated earlier at voltage levels from 0.1 V to 1 kV with excellent results. The advantages of this method are that it uses commonly available equipment and can be fully automated. We have made comparisons with three other low-voltage methods and the differences show that the uncertainties can be less than 30 μV/V at 1 mV and 3 μV/V at 10 mV, making it possible to use this method to perform automated calibration of calibrators with sufficient accuracy for calibration of high-end instruments. | |
653 | a dc range calibrators | |
653 | a dc voltage build-up | |
653 | a DC voltage ratio | |
653 | a dc voltage scale | |
653 | a low voltage measurements | |
653 | a DC voltage | |
653 | a Step method | |
700 | 1 | a Early, Murray D.u Measurement Standards Laboratory of New Zealand, New Zealand4 aut |
700 | 1 | a Eklund, Gunnaru RISE,SP – Sveriges Tekniska Forskningsinstitut4 aut0 (Swepub:ri)gunnare@ri.se |
700 | 1 | a Gunnarsson, Oveu RISE,SP – Sveriges Tekniska Forskningsinstitut4 aut |
700 | 1 | a Rydler, Karl-Eriku RISE,SP – Sveriges Tekniska Forskningsinstitut4 aut0 (Swepub:ri)KarlER@ri.se |
710 | 2 | a RISEb SP – Sveriges Tekniska Forskningsinstitut4 org |
773 | 0 | t CPEM Digest (Conference on Precision Electromagnetic Measurements)d : Institute of Electrical and Electronics Engineers Inc.g , s. 520-521q <520-521z 9781479952052 |
856 | 4 8 | u https://urn.kb.se/resolve?urn=urn:nbn:se:ri:diva-46527 |
856 | 4 8 | u https://doi.org/10.1109/CPEM.2014.6898488 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.
Kopiera och spara länken för att återkomma till aktuell vy