Sökning: onr:"swepub:oai:DiVA.org:umu-135578" >
Tibial component ro...
Tibial component rotation around the transverse axis measured by radiostereometry predicts aseptic loosening better than maximal total point motion A follow-up of 116 total knee arthroplasties after at least 15 years
-
- Gudnason, Asgeir (författare)
- Uppsala universitet,Ortopedi
-
- Adalberth, Gunnar (författare)
- Uppsala universitet,Ortopedi
-
- Nilsson, Kjell-Gunnar (författare)
- Umeå universitet,Institutionen för kirurgisk och perioperativ vetenskap,Univ Umea, Dept Surg & Perioperat Sci, Umea, Sweden.
-
visa fler...
-
- Hailer, Nils P (författare)
- Uppsala universitet,Ortopedi
-
visa färre...
-
(creator_code:org_t)
- 2017-03-07
- 2017
- Engelska.
-
Ingår i: Acta Orthopaedica. - : Medical Journals Sweden AB. - 1745-3674 .- 1745-3682. ; 88:3, s. 282-287
- Relaterad länk:
-
https://doi.org/10.1...
-
visa fler...
-
https://umu.diva-por... (primary) (Raw object)
-
https://www.tandfonl...
-
https://uu.diva-port... (primary) (Raw object)
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- Background and purpose - Maximal total point motion (MTPM) measured by radiostereometry (RSA) is widely used as a predictor of total knee arthroplasty (TKA) loosening. We compared the ability of different RSA measurements at different time points to predict loosening of tibial TKA components in the long term. Patients and methods - 116 TKAs in 116 patients were included in our analysis. 16 (14.8-17.4) years after surgery, 5 tibial components had been revised due to aseptic loosening. Receiver operating characteristic curves were calculated in order to investigate the specificity and sensitivity of different RSA parameters at different thresholds. Results - Rotation around the transverse (x-) axis measured 2 years postoperatively had the best predictive value of all parameters, with an area under the curve (AUC) of 80%. Using a threshold of 0.8 degrees, a specificity of 85% and a sensitivity of 50% were reached. The AUC for tibial component distal translation was 79% and it was 77% for proximal translation, whereas it was only 68% for MTPM. Interpretation - Rotation of the cemented tibial component around the transverse axis, proximal translation, and distal translation are slightly better at predicting aseptic loosening than MTPM, and tibial component migration measured after 2 years gives a good prediction of aseptic loosening up to 15 years.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Ortopedi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Orthopaedics (hsv//eng)
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas