SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:uu-347466"
 

Sökning: onr:"swepub:oai:DiVA.org:uu-347466" > Evaluating humidity...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00003691naa a2200397 4500
001oai:DiVA.org:uu-347466
003SwePub
008180403s2018 | |||||||||||000 ||eng|
024a https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-3474662 URI
024a https://doi.org/10.1175/JTECH-D-17-0072.12 DOI
040 a (SwePub)uu
041 a engb eng
042 9 SwePub
072 7a ref2 swepub-contenttype
072 7a art2 swepub-publicationtype
100a Nilsson, Erik,d 1983-u Uppsala universitet,Luft-, vatten- och landskapslära,Meteorologi, AWEP4 aut0 (Swepub:uu)erini203
2451 0a Evaluating humidity and sea salt disturbances on CO2 flux measurements
264 1c 2018
338 a print2 rdacarrier
520 a Global oceans are an important sink of atmospheric carbon dioxide (CO2). Therefore, understanding the air-sea flux of CO2 is a vital part in describing the global carbon balance. Eddy covariance (EC) measurements are often used to study CO2 fluxes from both land and ocean. CO2 are usually measured with infrared absorption sensors, which at the same time measure water vapor. Studies have shown that presence of water vapor fluctuations in the sampling air potentially result in erroneous CO2 flux measurements due to cross-sensitivity of the sensor. Here we compare measured CO2 fluxes from both enclosed path Li-Cor 7200 sensors and open-path Li-Cor 7500 instruments from an inland measurement site and a marine site. We also introduce new quality control criteria based upon a Relative Signal Strength Indicator (RSSI). The sampling gas in one of the Li-Cor 7200 instruments was dried by means of a multi-tube diffusion dryer so that the water vapor fluxes were close to zero. With this setup we investigated the effect that cross-sensitivity of the CO2 signal to water vapor can have on the CO2 fluxes. The dryer had no significant effect on the CO2 fluxes. We tested the hypothesis that the cross-sensitivity effect is caused by hygroscopic particles such as sea salt by spraying a saline solution on the windows of the Li-Cor 7200 instruments during the inland field test. Our results confirm earlier findings that sea salt contamination can affect CO2 fluxes significantly and confirm earlier findings, that drying the sampling air for the gas analyzer is an effective method to reduce this signal contamination.
650 7a NATURVETENSKAPx Geovetenskap och miljövetenskapx Meteorologi och atmosfärforskning0 (SwePub)105082 hsv//swe
650 7a NATURAL SCIENCESx Earth and Related Environmental Sciencesx Meteorology and Atmospheric Sciences0 (SwePub)105082 hsv//eng
653 a Meteorology
653 a Meteorologi
700a Bergström, Hans,d 1952-u Uppsala universitet,Luft-, vatten- och landskapslära4 aut0 (Swepub:uu)hansberg
700a Rutgersson, Anna,d 1971-u Uppsala universitet,Luft-, vatten- och landskapslära4 aut0 (Swepub:uu)aru27058
700a Podgrajsek, Evau Uppsala universitet,Luft-, vatten- och landskapslära4 aut0 (Swepub:uu)evapo461
700a Wallin, Marcus B.,d 1979-u Uppsala universitet,Luft-, vatten- och landskapslära4 aut0 (Swepub:uu)marwa654
700a Bergström, Gunnaru Uppsala universitet,Luft-, vatten- och landskapslära4 aut0 (Swepub:uu)gunbe943
700a Dellwik, Ebba4 aut
700a Landwehr, Sebastian4 aut
700a Ward, Brian4 aut
710a Uppsala universitetb Luft-, vatten- och landskapslära4 org
773t Journal of Atmospheric and Oceanic Technologyg 35, s. 859-875q 35<859-875x 0739-0572x 1520-0426
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-347466
8564 8u https://doi.org/10.1175/JTECH-D-17-0072.1

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy