SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:lup.lub.lu.se:45fb32cf-5a0d-449c-a29b-4cee145b55d6"
 

Search: onr:"swepub:oai:lup.lub.lu.se:45fb32cf-5a0d-449c-a29b-4cee145b55d6" > Test-Retest Reliabi...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00004332naa a2200373 4500
001oai:lup.lub.lu.se:45fb32cf-5a0d-449c-a29b-4cee145b55d6
003SwePub
008200708s2020 | |||||||||||000 ||eng|
024a https://lup.lub.lu.se/record/45fb32cf-5a0d-449c-a29b-4cee145b55d62 URI
024a https://doi.org/10.1089/lrb.2019.00442 DOI
040 a (SwePub)lu
041 a engb eng
042 9 SwePub
072 7a art2 swepub-publicationtype
072 7a ref2 swepub-contenttype
100a Jönsson, Charlottau Lund University,Lunds universitet,Människan i rörelse: hälsa och rehabilitering,Forskargrupper vid Lunds universitet,Human Movement: health and rehabilitation,Lund University Research Groups,Skåne University Hospital4 aut0 (Swepub:lu)ch3220jo
2451 0a Test-Retest Reliability of Volume and Local Tissue Water Measurements in Lower Limbs of Healthy Women and Men
264 1b Mary Ann Liebert Inc,c 2020
300 a 9 s.
520 a Background: Measurements of lower limb (LL) volume and local tissue water by tissue dielectric constant (TDC) are common in lymphedema management. Knowledge of normal variability in health subjects is important and can serve as a base for early lymphedema diagnosis but is currently lacking. The aim of this study was to evaluate test-retest reliability of LL volume and TDC values in healthy women and men. Methods and Results: Thirty-three women and 28 men were measured twice, 2 weeks apart. Volume was calculated from circumferential measurements every 4 cm and TDC in 14 points. Test-retest reliability was evaluated using intraclass correlation coefficient (ICC), changes in the mean, standard error of measurement in percentage (SEM%), and smallest real difference in percentage (SRD%). For volume, reliability was high (ICC 0.99) and measurement errors were low in both women and men (SEM%: 1.1%-1.3%; SRD%: 3.1%-3.6%). For TDC, reliability was fair to excellent in women (ICC 0.63-0.93) and poor to excellent in men (ICC 0.21-0.89). Measurement errors were acceptable in all points in women (SEM%: 3.9%-10.2%; SRD% 10.8%-28.2%), but only in 11 points in men (SEM%: 3.9%-14.5%; SRD%: 10.9%-40.1%). The points close to bone and tendons in men had lower reliability and higher measurement errors. Conclusion: Measurements of LL volume and TDC are reliable in healthy women and men; both methods can be recommended. However, TDC points close to bone and tendons in men should be used with caution.
650 7a MEDICIN OCH HÄLSOVETENSKAPx Medicinska och farmaceutiska grundvetenskaperx Fysiologi0 (SwePub)301062 hsv//swe
650 7a MEDICAL AND HEALTH SCIENCESx Basic Medicinex Physiology0 (SwePub)301062 hsv//eng
653 a anthropometry/instrumentation
653 a healthy volunteers
653 a lower extremity
653 a reproducibility of results
700a Bjurberg, Mariau Lund University,Lunds universitet,Huvud- och halscancergruppen,Forskargrupper vid Lunds universitet,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Head and Neck Cancer Research Group,Lund University Research Groups,LUCC: Lund University Cancer Centre,Other Strong Research Environments,Skåne University Hospital4 aut0 (Swepub:lu)onk-mbj
700a Brogårdh, Christinau Lund University,Lunds universitet,Människan i rörelse: hälsa och rehabilitering,Forskargrupper vid Lunds universitet,Human Movement: health and rehabilitation,Lund University Research Groups4 aut0 (Swepub:lu)med-cbg
700a Johansson, Karinu Lund University,Lunds universitet,Människan i rörelse: hälsa och rehabilitering,Forskargrupper vid Lunds universitet,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Human Movement: health and rehabilitation,Lund University Research Groups,LUCC: Lund University Cancer Centre,Other Strong Research Environments4 aut0 (Swepub:lu)sjuk-kjo
710a Människan i rörelse: hälsa och rehabiliteringb Forskargrupper vid Lunds universitet4 org
773t Lymphatic Research and Biologyd : Mary Ann Liebert Incg 18:3, s. 261-269q 18:3<261-269x 1539-6851x 1557-8585
856u http://dx.doi.org/10.1089/lrb.2019.0044y FULLTEXT
8564 8u https://lup.lub.lu.se/record/45fb32cf-5a0d-449c-a29b-4cee145b55d6
8564 8u https://doi.org/10.1089/lrb.2019.0044

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Jönsson, Charlot ...
Bjurberg, Maria
Brogårdh, Christ ...
Johansson, Karin
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Basic Medicine
and Physiology
Articles in the publication
Lymphatic Resear ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view