Sökning: onr:"swepub:oai:lup.lub.lu.se:afbee029-f673-4fd0-95a2-5545d9246508" > MRI image plane non...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00003832naa a2200433 4500
001oai:lup.lub.lu.se:afbee029-f673-4fd0-95a2-5545d9246508
003SwePub
008160816s1999 | |||||||||||000 ||eng|
024a https://lup.lub.lu.se/record/afbee029-f673-4fd0-95a2-5545d92465082 URI
024a https://doi.org/10.1016/S0730-725X(99)00081-82 DOI
040 a (SwePub)lu
041 a engb eng
042 9 SwePub
072 7a art2 swepub-publicationtype
072 7a ref2 swepub-contenttype
100a Magnusson, Peteru Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups4 aut0 (Swepub:lu)extLU-696
2451 0a MRI image plane nonuniformity in evaluation of ferrous sulphate dosimeter gel (FeGel) by means of T1-relaxation time
264 1c 1999
300 a 14 s.
520 a MR image nonuniformity can vary significantly with the spin-echo pulse sequence repetition time. When MR images with different nonuniformity shapes are used in a T1-calculation the resulting T1-image becomes nonuniform. As shown in this work the uniformity TR-dependence of the spin-echo pulse sequence is a critical property for T1 measurements in general and for ferrous sulfate dosimeter gel (FeGel) applications in particular. The purpose was to study the characteristics of the MR image plane nonuniformity in FeGel evaluation. This included studies of the possibility of decreasing nonuniformities by selecting uniformity optimized repetition times, studies of the transmitted and received RF-fields and studies of the effectiveness of the correction methods background subtraction and quotient correction. A pronounced MR image nonuniformity variation with repetition and T1 relaxation time was observed, and was found to originate from nonuniform RF-transmission in combination with the inherent differences in T1 relaxation for different repetition times. The T1 calculation itself, the uniformity optimized repetition times, nor none of the correction methods studied could sufficiently correct the nonuniformities observed in the T1 images. The nonuniformities were found to vary considerably less with inversion time for the inversion-recovery pulse sequence, than with repetition time for the spin-echo pulse sequence, resulting in considerably lower T1 image nonuniformity levels.
650 7a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Radiologi och bildbehandling0 (SwePub)302082 hsv//swe
650 7a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Radiology, Nuclear Medicine and Medical Imaging0 (SwePub)302082 hsv//eng
653 a Background Radiation
653 a Ferrous Compounds
653 a Gels
653 a Magnetic Resonance Imaging
653 a Phantoms, Imaging
653 a Radiation Dosage
653 a Radiometry
653 a Reference Standards
653 a Subtraction Technique
653 a Time Factors
700a Bäck, S Au Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups4 aut0 (Swepub:lu)rfa-sba
700a Olsson, L Eu Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups4 aut0 (Swepub:lu)rfa-lol
710a Medicinsk strålningsfysik, Malmöb Forskargrupper vid Lunds universitet4 org
773t Magnetic Resonance Imagingg 17:9, s. 70-1357q 17:9<70-1357x 0730-725X
856u http://dx.doi.org/10.1016/S0730-725X(99)00081-8y FULLTEXT
8564 8u https://lup.lub.lu.se/record/afbee029-f673-4fd0-95a2-5545d9246508
8564 8u https://doi.org/10.1016/S0730-725X(99)00081-8

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Magnusson, Peter
Bäck, S A
Olsson, L E
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Magnetic Resonan ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy