245 | 1 0 | a A Monte Carlo Investigation of the Dual Photopeak Window Scatter Correction Method |
264 | 1 | b Institute of Electrical and Electronics Engineers (IEEE),c 1993 |
520 | a Results from a Monte Carlo investigation of the dual photopeak window (DPW) scatter correction method are presented for point and extended sources of Tc-99m in both homogeneous and nonhomogeneous attenuating media. The DPW method uses the ratio of counts in two nonoverlapping energy windows within the photopeak region as input to a regression relation. A pixel-by-pixel estimate of the scatter in the summed windows is obtained and subtracted to yield an estimate of the primary. An approximate tenfold decrease in the scatter fraction and an excellent agreement with the shape of the true scatter distribution were observed. | |
650 | 7 | a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Radiologi och bildbehandling0 (SwePub)302082 hsv//swe |
650 | 7 | a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Radiology, Nuclear Medicine and Medical Imaging0 (SwePub)302082 hsv//eng |
700 | 1 | a Ljungberg, Michaelu Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine4 aut0 (Swepub:lu)rafy-mlj |
700 | 1 | a King, Michael A4 aut |
700 | 1 | a Glick, Stephen J4 aut |
710 | 2 | a Medicinsk strålningsfysik, Lundb Sektion V4 org |
773 | 0 | t IEEE Transactions on Nuclear Scienced : Institute of Electrical and Electronics Engineers (IEEE)g 40:2, s. 179-185q 40:2<179-185x 0018-9499x 1558-1578 |
856 | 4 | u http://dx.doi.org/10.1109/23.212338y FULLTEXT |
856 | 4 8 | u https://lup.lub.lu.se/record/1107351 |
856 | 4 8 | u https://doi.org/10.1109/23.212338 |