SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:lup.lub.lu.se:d5e0e0a1-10e5-4c57-86ec-89a3338020cc"
 

Search: onr:"swepub:oai:lup.lub.lu.se:d5e0e0a1-10e5-4c57-86ec-89a3338020cc" > Source localization...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Beniczky, Sandor (author)

Source localization of rhythmic ictal EEG activity: A study of diagnostic accuracy following STARD criteria

  • Article/chapterEnglish2013

Publisher, publication year, extent ...

  • 2013-08-14
  • Wiley,2013

Numbers

  • LIBRIS-ID:oai:lup.lub.lu.se:d5e0e0a1-10e5-4c57-86ec-89a3338020cc
  • https://lup.lub.lu.se/record/4171995URI
  • https://doi.org/10.1111/epi.12339DOI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:art swepub-publicationtype
  • Subject category:ref swepub-contenttype

Notes

  • PurposeAlthough precise identification of the seizure-onset zone is an essential element of presurgical evaluation, source localization of ictal electroencephalography (EEG) signals has received little attention. The aim of our study was to estimate the accuracy of source localization of rhythmic ictal EEG activity using a distributed source model. MethodsSource localization of rhythmic ictal scalp EEG activity was performed in 42 consecutive cases fulfilling inclusion criteria. The study was designed according to recommendations for studies on diagnostic accuracy (STARD). The initial ictal EEG signals were selected using a standardized method, based on frequency analysis and voltage distribution of the ictal activity. A distributed source modellocal autoregressive average (LAURA)was used for the source localization. Sensitivity, specificity, and measurement of agreement (kappa) were determined based on the reference standardthe consensus conclusion of the multidisciplinary epilepsy surgery team. Predictive values were calculated from the surgical outcome of the operated patients. To estimate the clinical value of the ictal source analysis, we compared the likelihood ratios of concordant and discordant results. Source localization was performed blinded to the clinical data, and before the surgical decision. Key FindingsReference standard was available for 33 patients. The ictal source localization had a sensitivity of 70% and a specificity of 76%. The mean measurement of agreement (kappa) was 0.61, corresponding to substantial agreement (95% confidence interval (CI) 0.38-0.84). Twenty patients underwent resective surgery. The positive predictive value (PPV) for seizure freedom was 92% and the negative predictive value (NPV) was 43%. The likelihood ratio was nine times higher for the concordant results, as compared with the discordant ones. SignificanceSource localization of rhythmic ictal activity using a distributed source model (LAURA) for the ictal EEG signals selected with a standardized method is feasible in clinical practice and has a good diagnostic accuracy. Our findings encourage clinical neurophysiologists assessing ictal EEGs to include this method in their armamentarium.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Lantz, Goran (author)
  • Rosenzweig, Ivana (author)
  • Åkeson, PerLund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups(Swepub:lu)ront-pak (author)
  • Pedersen, Birthe (author)
  • Pinborg, Lars H. (author)
  • Ziebell, Morten (author)
  • Jespersen, Bo (author)
  • Fuglsang-Frederiksen, Anders (author)
  • Diagnostisk radiologi, MalmöForskargrupper vid Lunds universitet (creator_code:org_t)

Related titles

  • In:Epilepsia: Wiley54:10, s. 1743-17520013-9580

Internet link

Find in a library

  • Epilepsia (Search for host publication in LIBRIS)

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view