SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:research.chalmers.se:cbe04adc-0ef7-44c3-9fa1-a0210d9cc12a"
 

Search: onr:"swepub:oai:research.chalmers.se:cbe04adc-0ef7-44c3-9fa1-a0210d9cc12a" > Design and manufact...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Design and manufacture procedures of phantoms for hyperthermia QA guidelines

de Lazzari, Mattia, 1996 (author)
Chalmers tekniska högskola,Chalmers University of Technology
Napieralski, Wojtek (author)
Chalmers tekniska högskola,Chalmers University of Technology
Nguyen, Thien (author)
Chalmers tekniska högskola,Chalmers University of Technology
show more...
Ström, Anna, 1976 (author)
Chalmers tekniska högskola,Chalmers University of Technology
Dobsicek Trefna, Hana, 1979 (author)
Chalmers tekniska högskola,Chalmers University of Technology
show less...
 (creator_code:org_t)
2023
2023
English.
In: 17th European Conference on Antennas and Propagation, EuCAP 2023.
  • Conference paper (peer-reviewed)
Abstract Subject headings
Close  
  • Clinical outcome of hyperthermia therapy (HT) is strongly correlated with the thermal dose delivered into the tumor. Achieving of prescribed temperature distribution within the target area should therefore the primary objective of any HT treatment. The Quality Assurance (QA) guidelines developed in past decennium by ESHO-TC establish the physical characterization and prescribe the safeguards to ensure that the clinically used equipment is capable of achieving adequate temperatures. The direct implementation of these guidelines is however limited by the lack of suitable phantom materials. To address this issue, we propose (i) a novel material to mimic fat tissue and (ii) a standardized phantom verification of phased array applicators for deep HT in Head and Neck (H&N) and extremities. In particular, (i) a fat-phantom composed of an ethylcellulose based oleogel exhibit equivalent dielectric and thermal properties with the required mechanical stability even at elevated temperatures, while (ii) the standardized phantom provides the means to capture the thermal profiles to evaluate the performance indicators in reproducible manner. Both phantoms thus bears a great potential for their extensive use in QA procedures.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk apparatteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Equipment Engineering (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

Modelling
Hyperthermia
Quality Assurance

Publication and Content Type

kon (subject category)
ref (subject category)

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
de Lazzari, Matt ...
Napieralski, Woj ...
Nguyen, Thien
Ström, Anna, 197 ...
Dobsicek Trefna, ...
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Medical Engineer ...
and Medical Equipmen ...
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Articles in the publication
By the university
Chalmers University of Technology

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view