SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:0365 5954
 

Sökning: L773:0365 5954 > Liver-specific cont...

Liver-specific contrast media for MRI and CT experimental studies

Leander, Peter (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups
 (creator_code:org_t)
1995
1995
Engelska.
Ingår i: Acta Radiologica. Supplementum. - 0365-5954. ; 396, s. 1-36
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • MRI and CT are modalities appropriate for liver imaging. To obtain higher sensitivity in diagnoses of focal lesions in the liver, contrast media (CM) are used. Non-specific extracellular CM are not optimal as they rapidly diffuse into both normal tissue and tumorous tissue. By two different mechanisms, the hepatobiliary route and targeting to the reticuloendothelial system, agents may accumulate in normal liver tissue, thereby giving liver-specific CM. So far no such agents have been approved for clinical use. In the present studies, animal models were used to investigate the imaging efficacy of experimental liver-specific CM and answer the following questions: i) Do these new liver-specific CM result in enhancement of normal liver? ii) If enhancement in normal liver is present, does this result in higher contrast of normal liver to tumorous tissue? iii) If higher contrast of normal liver to tumorous tissue is present, does this result in higher tumour detection-rates? Relative to non-enhanced and contrast-enhanced CT, what tumour detection-rate is obtained using non-enhanced and contrast-enhanced MRI? All the liver-specific CM studies possessed the ability to significantly alter the signal in normal liver tissue. Compared to precontrast values, the liver-specific CM studied in MRI (Mn-DPDP) and CT (IEEC-particles and iodixanol-liposomes) were able to increase significantly the contrast of normal liver tissue to tumorous tissue and the tumour detection-frequency in VX2-carcinoma liver tumour-bearing rabbits. In CT using a non-specific extracellular CM, iohexol, no improvement in contrast or tumour detection-frequency was obtained. As reflected in the values of contrast-to-noise obtained, MRI and CT have the same potential for tumour detection in the liver model used in the present studies. Liver-specific CM have the property of improving the contrast of normal liver tissue to tumorous tissue in MRI and CT, giving higher tumour detection-rates. Permitting intravenous administration and the use of long imaging-windows, liver-specific CM are easy to use.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Leander, Peter
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Acta Radiologica ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy