Imaging with multi-prism x-ray lenses

Fredenberg, Erik, PhD, 1979- (författare)
KTH,Medicinsk bildfysik,Albanova VinnExcellence Center for Protein Technology, ProNova
Cederström, Björn (författare)
KTH,Medicinsk bildfysik,Albanova VinnExcellence Center for Protein Technology, ProNova
Åslund, Magnus (författare)
visa fler...
Nillius, Peter (författare)
KTH,Medicinsk bildfysik,Albanova VinnExcellence Center for Protein Technology, ProNova
Lundqvist, Mats (författare)
Danielsson, Mats (författare)
KTH,Medicinsk bildfysik,Albanova VinnExcellence Center for Protein Technology, ProNova
visa färre...
 (creator_code:org_t)
SPIE, 2008
2008
Engelska.
Ingår i: Medical Imaging 2008 - Physics of Medical Imaging. - : SPIE. - 9780819470973 ; , s. 91308-91308
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • The multi-prism lens (MPL) is a refractive x-ray lens consisting of two rows of prisms facing each other at an angle. Rays entering the lens at the periphery will encounter a larger number of prisms than will central ones, hence experiencing a greater refraction. The focusing effect of the MPL can be used to gather radiation from a large aperture onto a smaller detector, and accordingly to make better use of the available x-ray flux in medical x-ray imaging. Potential advantages of a better photon economy include shorter acquisition times, a reduced tube loading, or an improved resolution. Since the focusing effect is one-dimensional it matches the design of scanning systems. In this study we present the first images acquired with an MPL instead of the pre-breast slit collimator in a scanning mammography system. According to the measurements, the MPL is able to increase the flux 32% at equal resolution compared to the slit collimator, or to improve the resolution 2.4 mm(-1) at equal flux. If used with a custom-made absorption filter in a clinical set-up, the gain of flux of the MPL is expected to be at least 45%, and the corresponding improvement in resolution to be 3 mm(-1).

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Biomedicinsk laboratorievetenskap/teknologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Biomedical Laboratory Science/Technology (hsv//eng)

Nyckelord

mammography
x-ray optics
multi-prism lens
pre-breast slit-collimator
x-ray flux
acquisition time
resolution
Medical technology
Medicinsk teknik

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy