SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Thomson AM)
 

Sökning: WFRF:(Thomson AM) > (2020-2023) > Self-rated joint hy...

Self-rated joint hypermobility : the five-part questionnaire evaluated in a Swedish non-clinical adult population

Glans, Martin, 1985- (författare)
Örebro universitet,Institutionen för medicinska vetenskaper,University Health Care Research Centre
Humble, Mats B., 1952- (författare)
Örebro universitet,Institutionen för medicinska vetenskaper,University Health Care Research Centre
Elwin, Marie, 1953- (författare)
Örebro universitet,Institutionen för medicinska vetenskaper,Region Örebro län,University Health Care Research Centre
visa fler...
Bejerot, Susanne, 1955- (författare)
Örebro universitet,Institutionen för medicinska vetenskaper,University Health Care Research Centre
visa färre...
 (creator_code:org_t)
2020-03-17
2020
Engelska.
Ingår i: BMC Musculoskeletal Disorders. - : BioMed Central. - 1471-2474. ; 21:1
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND: The conventional way to identify generalised joint hypermobility is by a physical examination according to the Beighton Score. However, a physical examination is time-consuming in clinical practise and may be unfeasible in population-based studies. The self-assessment five-part questionnaire on hypermobility (5PQ) offers a more practicable way to identify GJH. The aim of this study was to test validity and reliability of the five-part questionnaire on hypermobility (5PQ) translated into Swedish on a non-clinical adult population.METHODS: A structured procedure was used for the translation of the 5PQ into Swedish. The Beighton Score was used as reference standard for generalised joint hypermobility. Test-retest reliability was tested in a separate group who filled in the questionnaire twice with a ten-week interval. Participants consisted of a convenience sample recruited in Stockholm, Sweden (2017).RESULTS: A total of 328 participants were included in the study, 297 participants in the validity group and 31 participants in the reliability group. When evaluated against a present Beighton Score with an age-dependent cut-off, the Swedish 5PQ attained a sensitivity of 91%, a specificity of 75% and an area under the curve of 0.87. The Swedish 5PQ showed substantial to almost perfect test-retest reliability.CONCLUSIONS: The Swedish 5PQ is a valid and reliable instrument to screen for or to identify generalised joint hypermobility.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Arbetsterapi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Occupational Therapy (hsv//eng)

Nyckelord

Diagnostic self evaluation
Hypermobility
Joint instability
Surveys and questionnaires
Translation
Validation

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy