SwePub
Sök i LIBRIS databas

  Utökad sökning

(WFRF:(Normann Fredrik 1982)) srt2:(2015-2019)
 

Sökning: (WFRF:(Normann Fredrik 1982)) srt2:(2015-2019) > (2015) > Heat extraction fro...

Heat extraction from a utility-scale oxy-fuel-fired CFB boiler

Seddighi, Sadegh, 1977 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Pallarès, David, 1975 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Normann, Fredrik, 1982 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa fler...
Johnsson, Filip, 1960 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa färre...
 (creator_code:org_t)
Elsevier BV, 2015
2015
Engelska.
Ingår i: Chemical Engineering Science. - : Elsevier BV. - 0009-2509. ; 130, s. 144-150
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The temperature and heal extraction parameters of a utility-scale, oxy-fuel-fired boiler are investigated using a mathematical model that was originally developed and validated with data from 100-kW(th) to 4-MWth, oxy-fuel-fired circulating fluidized bed units. This work involves an existing furnace, which was developed for air bring, and evaluates its operational potentials under oxy-fuel conditions, allowing additional heat extraction through an external heat exchanger (EHE). The modeling shows that even though the heat extraction levels from the entire furnace, flue gas pass, and EHE increase with increases in the inlet 02 concentration, the heat extraction from the EHE dominates the heat extraction for high inlet 02 concentrations and, consequently, requires an increase in the circulating solids flow, which transfers heat from the furnace to the seal. While maintaining the same dense bed temperature as in the air Fired case, an increased inlet 02 concentration in the oxy-fired case leads to dramatic increases in the maximum in furnace temperature and maximum heat extraction flux rate. Thus, to control the maximum furnace temperature, the circulating solids flux must be increased beyond what is required to close the heat balance across the CFB loop. For the conditions investigated, limitation of the maximum furnace temperature to 1273 K yields that 48%, 56%, and 70% are the highest possible inlet oxygen concentrations if the external circulation flux rate is limited to 10, 20, and 30 kg/m(2)/s, respectively.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Kemiteknik -- Kemiska processer (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Chemical Engineering -- Chemical Process Engineering (hsv//eng)

Nyckelord

Gas solids flow
Design
Heat transfer
Scale up
External heat exchanger (EHE)
Oxy-fuel combustion

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy