SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Lindström Marianne)
 

Sökning: WFRF:(Lindström Marianne) > Estimation of Blood...

Estimation of Blood Loss in Oral and Maxillofacial Surgery by Measurements of Low Haemoglobin Levels in Mixtures of Blood, Saliva and Saline : a Laboratory Study

Johansson, Krister (författare)
Malmö universitet,Odontologiska fakulteten (OD),Department of Oral & Maxillofacial Surgery, Skåne University Hospital, Lund, Sweden
Lindström, Martin (författare)
Malmö universitet,Odontologiska fakulteten (OD)
Alhabshi, Manaf (författare)
Malmö universitet,Odontologiska fakulteten (OD)
visa fler...
Ahmad, Marianne (författare)
Malmö universitet,Odontologiska fakulteten (OD)
Svensson, Peter J. (författare)
Department of Translational Medicine, Clinical Coagulation Research Unit, Skåne University Hospital, Malmö, Sweden
Becktor, Jonas P (författare)
Malmö universitet,Odontologiska fakulteten (OD)
visa färre...
 (creator_code:org_t)
2021-06-30
2021
Engelska.
Ingår i: Journal of Oral & Maxillofacial Research. - : Stilus Optimus. - 2029-283X. ; 12:2
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objectives: Estimating blood loss is an important factor in several surgical procedures. The accuracy of blood loss measurements in situations where blood is mixed with saliva and saline is however uncertain. The purpose of this laboratory study was to ascertain if blood loss measurements in mixtures of blood, saline, and saliva are reliable and could be applicable in a clinical setting.Material and Methods: Venous blood and resting saliva were collected from six volunteers. Saliva, saline, and combinations thereof were mixed with blood to obtain different concentrations. A portable spectrophotometer was first used to measure the haemoglobin concentration in undiluted venous blood followed by measurements of the haemoglobin concentration after each dilution. To examine the strength of linear relationships, linear regression and Pearson correlations were used.Results: The measurements of haemoglobin concentrations in mixtures of blood, saline, and saliva were proven to be accurate for haemoglobin measurements > 0.3 g/dl (correlation = 0.986 to 1). For haemoglobin measurements < 0.3 g/dl, a small increase in haemoglobin values were reported, which was directly associated to the saliva concentration in the solution (correlation = 0.983 to 1). This interference of saliva was significantly eliminated by diluting the samples with saline, mimicking the clinical situation.Conclusions: The results suggest that a portable spectrophotometer can be used clinically to preoperatively measure the haemoglobin value of a venous blood sample and postoperatively measure the haemoglobin value of the collected liquids, including shed blood, thereby achieving a highly accurate method of measuring blood loss during oral and maxillofacial surgery.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Nyckelord

oral surgery
postoperative hemorrhage
saliva
surgical blood loss

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy