SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Sorensson P)
 

Search: WFRF:(Sorensson P) > (2020-2023) > Comprehensive Cardi...

Comprehensive Cardiovascular Magnetic Resonance Diastolic Dysfunction Grading Shows Very Good Agreement Compared With Echocardiography

Ramos, J. G. (author)
Fyrdahl, A. (author)
Karolinska Institutet
Wieslander, B. (author)
Karolinska Institutet
show more...
Thalen, S. (author)
Karolinska Institutet
Reiter, G. (author)
Reiter, U. (author)
Jin, N. (author)
Maret, E. (author)
Karolinska Institutet
Eriksson, M. (author)
Caidahl, Kenneth, 1949 (author)
Karolinska Institutet,Gothenburg University,Göteborgs universitet,Institutionen för medicin,Institute of Medicine
Sorensson, P. (author)
Karolinska Institutet
Sigfridsson, A. (author)
Karolinska Institutet
Ugander, M. (author)
Karolinska Institutet
show less...
 (creator_code:org_t)
Elsevier BV, 2020
2020
English.
In: Jacc-Cardiovascular Imaging. - : Elsevier BV. - 1936-878X .- 1876-7591. ; 13:12, s. 2530-2542
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • OBJECTIVES The aims of this study were to develop a comprehensive cardiovascular magnetic resonance (CMR) approach to diastolic dysfunction (DD) grading and to evaluate the accuracy of CMR in the diagnosis of DD compared with echocardiography. BACKGROUND Left ventricular DD is routinely assessed using echocardiography. METHODS Consecutive clinically referred patients (n = 46; median age 59 years; interquartile range: 46 to 68 years; 33% women) underwent both conventional echocardiography and CMR. CMR diastolic transmitral velocities (E and A) and myocardial tissue velocity (e0) were measured during breath-hold using a validated high-temporal resolution radial sector-wise golden-angle velocity-encoded sequence. CMR pulmonary artery pressure was estimated from 4-dimensional flow analysis of blood flow vortex duration in the pulmonary artery. CMR left atrial volume was measured using the biplane long-axis area-length method. Both CMR and echocardiographic data were used to perform blinded grading of DD according to the 2016 joint American and European recommendations. RESULTS Grading of DD by CMR agreed with that by echocardiography in 43 of 46 cases (93%), of which 9% were normal, 2% indeterminate, 63% grade 1 DD, 4% grade 2 DD, and 15% grade 3 DD. There was a very good categorical agreement, with a weighted Cohen kappa coefficient of 0.857 (95% confidence interval: 0.73 to 1.00; p < 0.001). CONCLUSIONS A comprehensive CMR protocol for grading DD encompassing diastolic blood and myocardial velocities, estimated pulmonary artery pressure, and left atrial volume showed very good agreement with echocardiography. (C) 2020 by the American College of Cardiology Foundation.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Keyword

diastolic dysfunction
echocardiography
magnetic resonance imaging
main pulmonary-artery
heart-failure
volume
area
diagnosis
Cardiovascular System & Cardiology
Radiology
Medical Imaging

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view