Sökning: (db:Swepub) pers:(Persson Anders) lar1:(oru) >
Virtual non-contras...
Virtual non-contrast dual-energy CT compared to single-energy CT of the urinary tract : a prospective study
-
- Lundin, Margareta (författare)
- Department of Radiology, Örebro University Hospital, Örebro University, Örebro, Sweden,Department of Radiology, Örebro University Hospital, 701 85 Örebro, Sweden
-
- Liden, Mats, 1976- (författare)
- Örebro universitet,Institutionen för hälsovetenskap och medicin,Department of Radiology, Örebro University Hospital, Örebro University, Örebro, Sweden,Department of Radiology, Örebro University Hospital, 701 85 Örebro, Sweden
-
- Magnusson, A, (författare)
- Department of Radiology, Örebro University Hospital, 701 85 Örebro, Sweden,Clinical Epidemiology and Biostatistic Unit, Örebro University Hospital, Örebro, Sweden
-
visa fler...
-
- Abdulilah Mohammed, A. (författare)
- Department of Radiology, Örebro University Hospital, 701 85 Örebro, Sweden,Department of Radiology, Linköping University Hospital, Linköping, Sweden
-
- Geijer, Håkan, 1961- (författare)
- Örebro universitet,Institutionen för hälsovetenskap och medicin,Department of Radiology, Örebro University Hospital, Örebro University, Örebro, Sweden,Department of Radiology, Örebro University Hospital, 701 85 Örebro, Sweden
-
- Andersson, Torbjörn (författare)
- Örebro universitet,Linköpings universitet,Medicinsk radiologi,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Hälsouniversitetet,Institutionen för hälsovetenskap och medicin,Department of Radiology, Örebro University Hospital, Örebro University, Örebro, Sweden
-
- Persson, Anders (författare)
- Östergötlands Läns Landsting,Linköpings universitet,Medicinsk radiologi,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Hälsouniversitetet,Röntgenkliniken i Linköping,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
-
visa färre...
-
(creator_code:org_t)
- 2012-07-01
- 2012
- Engelska.
-
Ingår i: Acta Radiologica. - : Informa Healthcare. - 0284-1851 .- 1600-0455. ; 53:6, s. 689-694
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- Background: Dual-energy computed tomography (DECT) has been shown to be useful for subtracting bone or calcium in CT angiography and gives an opportunity to produce a virtual non-contrast-enhanced (VNC) image from a series where contrast agents have been given intravenously. High noise levels and low resolution have previously limited the diagnostic value of the VNC images created with the first generation of DECT. With the recent introduction of a second generation of DECT, there is a possibility of obtaining VNC images with better image quality at hopefully lower radiation dose compared to the previous generation.Purpose: The aim of this study is to compare the image quality of the single-energy series to a VNC series obtained with a two generations of DECT scanners. CT of the urinary tract was used as a model.Material and Methods: Thirty patients referred for evaluation of haematuria were examined with an older system (Somatom Definition) and another 30 patients with a new generation (Somatom Definition Flash). One single-energy series was obtained before and one dual-energy series after administration of intravenous contrast media. We created a VNC series from the contrast-enhanced images. Images were assessed concerning image quality with a visual grading scale evaluation of the VNC series with the single-energy series as gold standard.Results: The image quality of the VNC images was rated inferior to the single-energy variant for both scanners, OR range 11.5-67.3 for the Definition and OR 2.1-2.8 for the Definition Flash. Visual noise and overall quality were regarded as better with Flash than Definition.Conclusions: Image quality of VNC images obtained with the new generation of DECT is still slightly inferior compared to native images. However the difference is smaller with the new compared to the older system.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
Nyckelord
- Dual-energy computed tomography
- image quality
- urinary tract imaging
- virtual non-enhanced image series
- bone-iodine differentiation
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas