SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1755 3768 OR L773:1755 375X
 

Sökning: L773:1755 3768 OR L773:1755 375X > Comparison of clini...

Comparison of clinicians and an artificial neural network regarding accuracy and certainty in performance of visual field assessment for the diagnosis of glaucoma.

Andersson, Sabina (författare)
Lund University,Lunds universitet,Oftalmologi (Malmö),Forskargrupper vid Lunds universitet,Ophthalmology (Malmö),Lund University Research Groups
Heijl, Anders (författare)
Lund University,Lunds universitet,Oftalmologi (Malmö),Forskargrupper vid Lunds universitet,Ophthalmology (Malmö),Lund University Research Groups
Bizios, Dimitrios (författare)
Lund University,Lunds universitet,Oftalmologi (Malmö),Forskargrupper vid Lunds universitet,Ophthalmology (Malmö),Lund University Research Groups
visa fler...
Bengtsson, Boel (författare)
Lund University,Lunds universitet,Oftalmologi (Malmö),Forskargrupper vid Lunds universitet,Ophthalmology (Malmö),Lund University Research Groups
visa färre...
 (creator_code:org_t)
2012-05-15
2013
Engelska.
Ingår i: Acta Ophthalmologica. - : Wiley. - 1755-3768 .- 1755-375X. ; 91:5, s. 413-417
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: To compare clinicians and a trained artificial neural network (ANN) regarding accuracy and certainty of assessment of visual fields for the diagnosis of glaucoma. Methods: Thirty physicians with different levels of knowledge and experience in glaucoma management assessed 30-2 SITA Standard visual field printouts that included full Statpac information from 99 patients with glaucomatous optic neuropathy and 66 healthy subjects. Glaucomatous eyes with perimetric mean deviation values worsethan -10 dB were not eligible. The fields were graded on a scale of 1-10, where 1 indicated healthy with absolute certaintyand 10 signified glaucoma; 5.5 was the cut-off between healthy and glaucoma. The same fields were classified by a previously trained ANN. The ANN output was transformed into a linear scale that matched the scale used in the subjective assessments. Classification certainty was assessed using a classification error score. Results: Among the physicians, sensitivity ranged from 61% to 96% (mean 83%) and specificity from 59% to 100% (mean 90%). Our ANN achieved 93% sensitivity and 91% specificity, and it was significantly more sensitive than the physicians (p < 0.001) at a similar level of specificity. The ANN classification error score was equivalent to the top third scores of all physicians, and the ANN never indicated a high degree of certainty for any of its misclassified visual field tests. Conclusion: Our results indicate that a trained ANN performs at least as well as physicians in assessments of visual fields for the diagnosis of glaucoma.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Oftalmologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Ophthalmology (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Andersson, Sabin ...
Heijl, Anders
Bizios, Dimitrio ...
Bengtsson, Boel
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Oftalmologi
Artiklar i publikationen
Acta Ophthalmolo ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy