SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Dunker Dennis)
 

Sökning: WFRF:(Dunker Dennis) > Observer variation ...

Observer variation for radiography, computed tomography, and magnetic resonance imaging of occult hip fractures

Collin, David (författare)
Dunker, Dennis (författare)
Göthlin, Jan (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
visa fler...
Geijer, Mats (författare)
Gothenburg University,Göteborgs universitet,Lund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Institutionen för kliniska vetenskaper, Avdelningen för radiologi,Institute of Clinical Sciences, Department of Radiology
visa färre...
 (creator_code:org_t)
2011-10-01
2011
Engelska.
Ingår i: Acta Radiologica. - : SAGE Publications. - 1600-0455 .- 0284-1851. ; 52:8, s. 871-874
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Conventional radiography is insufficient for diagnosis in a small but not unimportant number of hip fractures, and secondary imaging with computed tomography (CT) or magnetic resonance imaging (MRI) is warranted. There are no convincing observer variation studies performed for conventional radiography or CT in occult fractures, and no large materials for MRI. Purpose: To assess observer variation in radiography, CT and MRI of suspected occult, non-displaced hip fractures, and to evaluate to what extent observer experience or patient age may influence observer performance. Material and Methods: A total of 375 patients after hip trauma where radiography was followed by CT or MRI to evaluate a suspected occult hip fracture were collected retrospectively from two imaging centers. After scoring by three observers with varying degrees of radiologic experience, observer variation was assessed by using linear weighted kappa statistics. Results: For radiography, agreements between the three observers were moderate to substantial for intracapsular fractures, with kappa values in the ranges of 0.56-0.66. Kappa values were substantial for extracapsular fractures, in the ranges of 0.69-0.72. With increasing professional experience, fewer fractures were classified as equivocal at radiography. For CT and MRI, observer agreements were similar and almost perfect, with kappa values in the ranges of 0.85-0.97 and 0.93-0.97. Conclusion: There were almost perfect observer agreements for CT and MRI in diagnosing non-displaced, occult hip fractures. Observer agreements for radiography were moderate to substantial, and observer experience influenced agreement only at radiography.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Hip fracture diagnosis
observer variation
radiography
computed
tomography
magnetic resonance imaging
quality assurance
computed tomography

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Collin, David
Dunker, Dennis
Göthlin, Jan
Geijer, Mats
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Acta Radiologica
Av lärosätet
Lunds universitet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy