Sökning: WFRF:(Hagiwara Akifumi) >
Cross-vendor multip...
Cross-vendor multiparametric mapping of the human brain using 3D-QALAS: A multicenter and multivendor study
-
- Fujita, Shohei (författare)
- Juntendo Univ, Japan; Univ Tokyo, Japan; Athinoula A Martinos Ctr Biomed Imaging, MA USA; Harvard Med Sch, MA USA
-
- Gagoski, Borjan (författare)
- Harvard Med Sch, MA USA; Boston Childrens Hosp, MA USA
-
- Hwang, Ken-Pin (författare)
- MD Anderson Canc Ctr, TX USA
-
visa fler...
-
- Hagiwara, Akifumi (författare)
- Juntendo Univ, Japan
-
- Warntjes, Marcel Jan Bertus (författare)
- Linköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,SyntheticMR, Linkoping, Sweden
-
- Fukunaga, Issei (författare)
- Juntendo Univ, Japan
-
- Uchida, Wataru (författare)
- Juntendo Univ, Japan
-
- Saito, Yuya (författare)
- Juntendo Univ, Japan
-
- Sekine, Towa (författare)
- Juntendo Univ, Japan
-
- Tachibana, Rina (författare)
- Juntendo Univ, Japan
-
- Muroi, Tomoya (författare)
- Juntendo Univ, Japan
-
- Akatsu, Toshiya (författare)
- Juntendo Univ, Japan
-
- Kasahara, Akihiro (författare)
- Univ Tokyo, Japan
-
- Sato, Ryo (författare)
- Univ Tokyo, Japan
-
- Ueyama, Tsuyoshi (författare)
- Univ Tokyo, Japan
-
- Andica, Christina (författare)
- Juntendo Univ, Japan; Juntendo Univ, Japan
-
- Kamagata, Koji (författare)
- Juntendo Univ, Japan
-
- Amemiya, Shiori (författare)
- Univ Tokyo, Japan
-
- Takao, Hidemasa (författare)
- Univ Tokyo, Japan
-
- Hoshino, Yasunobu (författare)
- Juntendo Univ, Japan
-
- Tomizawa, Yuji (författare)
- Juntendo Univ, Japan
-
- Yokoyama, Kazumasa (författare)
- Juntendo Univ, Japan
-
- Bilgic, Berkin (författare)
- Athinoula A Martinos Ctr Biomed Imaging, MA USA; Harvard Med Sch, MA USA; Harvard MIT Hlth Sci & Technol, MA USA
-
- Hattori, Nobutaka (författare)
- Juntendo Univ, Japan
-
- Abe, Osamu (författare)
- Univ Tokyo, Japan
-
- Aoki, Shigeki (författare)
- Juntendo Univ, Japan
-
visa färre...
-
(creator_code:org_t)
- 2024
- 2024
- Engelska.
-
Ingår i: Magnetic Resonance in Medicine. - : WILEY. - 0740-3194 .- 1522-2594.
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Purpose: To evaluate a vendor-agnostic multiparametric mapping scheme based on 3D quantification using an interleaved Look-Locker acquisition sequence with a T2 preparation pulse (3D-QALAS) for whole-brain T1, T2, and proton density (PD) mapping.Methods: This prospective, multi-institutional study was conducted between September 2021 and February 2022 using five different 3T systems from four prominent MRI vendors. The accuracy of this technique was evaluated using a standardized MRI system phantom. Intra-scanner repeatability and inter-vendor reproducibility of T1, T2, and PD values were evaluated in 10 healthy volunteers (6 men; mean age +/- SD, 28.0 +/- 5.6 y) who underwent scan-rescan sessions on each scanner (total scans = 100). To evaluate the feasibility of 3D-QALAS, nine patients with multiple sclerosis (nine women; mean age +/- SD, 48.2 +/- 11.5 y) underwent imaging examination on two 3T MRI systems from different manufacturers.Results: Quantitative maps obtained with 3D-QALAS showed high linearity (R2 = 0.998 and 0.998 for T1 and T2, respectively) with respect to reference measurements. The mean intra-scanner coefficients of variation for each scanner and structure ranged from 0.4% to 2.6%. The mean structure-wise test-retest repeatabilities were 1.6%, 1.1%, and 0.7% for T1, T2, and PD, respectively. Overall, high inter-vendor reproducibility was observed for all parameter maps and all structure measurements, including white matter lesions in patients with multiple sclerosis.Conclusion: The vendor-agnostic multiparametric mapping technique 3D-QALAS provided reproducible measurements of T1, T2, and PD for human tissues within a typical physiological range using 3T scanners from four different MRI manufacturers.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
Nyckelord
- cross-vendor technique; data pooling; multiparametric mapping; quantitative magnetic resonance imaging; relaxation time; relaxometry
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Fujita, Shohei
-
Gagoski, Borjan
-
Hwang, Ken-Pin
-
Hagiwara, Akifum ...
-
Warntjes, Marcel ...
-
Fukunaga, Issei
-
visa fler...
-
Uchida, Wataru
-
Saito, Yuya
-
Sekine, Towa
-
Tachibana, Rina
-
Muroi, Tomoya
-
Akatsu, Toshiya
-
Kasahara, Akihir ...
-
Sato, Ryo
-
Ueyama, Tsuyoshi
-
Andica, Christin ...
-
Kamagata, Koji
-
Amemiya, Shiori
-
Takao, Hidemasa
-
Hoshino, Yasunob ...
-
Tomizawa, Yuji
-
Yokoyama, Kazuma ...
-
Bilgic, Berkin
-
Hattori, Nobutak ...
-
Abe, Osamu
-
Aoki, Shigeki
-
visa färre...
- Om ämnet
-
- MEDICIN OCH HÄLSOVETENSKAP
-
MEDICIN OCH HÄLS ...
-
och Klinisk medicin
-
och Radiologi och bi ...
- Artiklar i publikationen
-
Magnetic Resonan ...
- Av lärosätet
-
Linköpings universitet