Sökning: WFRF:(Löfgren Burström Anna) > (2015-2019) > The Combined Value ...
Fältnamn | Indikatorer | Metadata |
---|---|---|
000 | 03964naa a2200397 4500 | |
001 | oai:DiVA.org:umu-171108 | |
003 | SwePub | |
008 | 200526s2019 | |||||||||||000 ||eng| | |
024 | 7 | a https://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-1711082 URI |
024 | 7 | a https://doi.org/10.33552/AJGH.2019.01.0005142 DOI |
040 | a (SwePub)umu | |
041 | a engb eng | |
042 | 9 SwePub | |
072 | 7 | a vet2 swepub-contenttype |
072 | 7 | a art2 swepub-publicationtype |
100 | 1 | a Eklöf, Vincy,d 1984-u Umeå universitet,Patologi4 aut0 (Swepub:umu)viyekf03 |
245 | 1 0 | a The Combined Value of Faecal Haemoglobin andCalprotectin in Diagnosis of Colorectal Cancer inSymptomatic Patients Referred to Colonoscopy |
264 | 1 | a San Fransisco :b Iris Publishers,c 2019 |
338 | a electronic2 rdacarrier | |
520 | a Aim: To investigate the diagnostic value of a combined analyses of faecal immunological haemoglobin (FIT) and faecal calprotectin (FC) in detection of colorectal cancer (CRC).Methods: Out-patients (n=1440) referred to the endoscopy unit were analysed for FIT and FC in stool samples collected before the colonoscopy bowel preparation. The samples were collected from one defecation by the patients at home. Patients with IBD were excluded leaving stool samples from 1133 patients for further analyses. FIT was analysed using the immunological Analyse F.O.B Test and FC was analysed using the CALPRO® Calprotectin Elisa Test. Sensitivity and specificity to detect CRC was calculated for the individual tests, as well as for combined FIT/FC tests.Results: Out of the included patients, 38 were diagnosed with CRC, 9 with high grade dysplasia (HGD), and 133 with low grade dysplasia (LGD). FIT was analysed in 673 (59.4%), FC in 1021 (90.1%) and both FIT and FC in 561 (49.5%) patients. A ROC curve analysis showed that the most accurate cut-off level for FC in detecting CRC in our study was 105.5 µg/g. The sensitivity for CRC when using FIT, FC (cut-off > 100 µg/g) and the combination of FIT and FC (at least one positive test) was 65.5%, 74.1% and 94.4%, respectively. The corresponding specificity was 84.8%, 74.9% and 68.3%, respectively.Conclusion: Combined analyses of FIT and FC improved sensitivity for detection of CRC. Further studies in larger cohorts are required to find the optimal cut-off levels for different combinations of tests. | |
650 | 7 | a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Cancer och onkologi0 (SwePub)302032 hsv//swe |
650 | 7 | a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Cancer and Oncology0 (SwePub)302032 hsv//eng |
653 | a Colorectal cancer; F-Calprotectin; F-Hb: Faecal markers; Screening markers | |
700 | 1 | a Lundgren, Davidu Umeå universitet,Institutionen för folkhälsa och klinisk medicin4 aut0 (Swepub:umu)dadlun96 |
700 | 1 | a Karling, Pontusu Umeå universitet,Institutionen för folkhälsa och klinisk medicin4 aut0 (Swepub:umu)peakag84 |
700 | 1 | a Wikberg, Maria L.u Umeå universitet,Patologi4 aut0 (Swepub:umu)mahe0061 |
700 | 1 | a Edin, Sofiau Umeå universitet,Patologi4 aut0 (Swepub:umu)soed0001 |
700 | 1 | a Löfgren Burström, Annau Umeå universitet,Patologi4 aut0 (Swepub:umu)anlo0002 |
700 | 1 | a Rutegård, Jörgen,d 1948-u Umeå universitet,Kirurgi4 aut0 (Swepub:umu)jaru0001 |
700 | 1 | a Palmqvist, Richardu Umeå universitet,Patologi4 aut0 (Swepub:umu)ripa0001 |
710 | 2 | a Umeå universitetb Patologi4 org |
773 | 0 | t Academic Journal of Gastroenterology & Hepatology (AJGH)d San Fransisco : Iris Publishersg 1:3, s. 1-7q 1:3<1-7 |
856 | 4 | u https://irispublishers.com/ajgh/abstract/the-combined-value-of-faecal-haemoglobin-and-calprotectin-in-diagnosis-of-colorectal-cancer.ID.000514.phpy URL |
856 | 4 | u https://umu.diva-portal.org/smash/get/diva2:1432316/FULLTEXT01.pdfx primaryx Raw objecty fulltext:print |
856 | 4 8 | u https://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-171108 |
856 | 4 8 | u https://doi.org/10.33552/AJGH.2019.01.000514 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.
Kopiera och spara länken för att återkomma till aktuell vy