Sökning: WFRF:(Pellegrini Paolo) > Monte Carlo Simulat...
Fältnamn | Indikatorer | Metadata |
---|---|---|
000 | 03704naa a2200445 4500 | |
001 | oai:DiVA.org:kth-242750 | |
003 | SwePub | |
008 | 190219s2016 | |||||||||||000 ||eng| | |
024 | 7 | a https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-2427502 URI |
024 | 7 | a https://doi.org/10.1109/NSSMIC.2016.80695372 DOI |
040 | a (SwePub)kth | |
041 | a engb eng | |
042 | 9 SwePub | |
072 | 7 | a ref2 swepub-contenttype |
072 | 7 | a kon2 swepub-publicationtype |
100 | 1 | a Borrarzo, Cristianu Sapienza Univ Rome, Dept Mol Med, Rome, Italy.4 aut |
245 | 1 0 | a Monte Carlo Simulation to Evaluate Factors Affecting Imaging Performances of Compact Scintillation Gamma Camara |
264 | 1 | b IEEE,c 2016 |
338 | a print2 rdacarrier | |
500 | a QC 20190219 | |
520 | a In recent years, a new generation of compact gamma cameras, based on monolithic scintillation crystals, has become increasingly widespread. The main advantages of small FoV gamma cameras with respect to the standard ones are high portability, low cost and low weight, allowing several clinical applications, from scintimammography to intraoperative tumor localization. In gamma cameras based on continuous scintillation crystals, intrinsic Spatial Resolution (SR) is mainly affected by two factors: scintillation light collection efficiency and overall crystal thickness. The first affects the counting statistics, the latter impacts on the light distribution width. To fully investigate the potentiality of these devices we took advantage of Monte Carlo simulations as a valuable tool to physically characterize the imaging systems and to establish a priori reference values. GEANT4 toolkit allows to completely describe the phenomenon of light emission and propagation through the media, providing control to all second-order factors existing in real systems. Results show clearly that SR is dependent on the number of photoelectrons produced and on the light spread. Furthermore, the role of refractive index has been unambiguously identified as an important factor affecting light collection and consequently SR. | |
650 | 7 | a TEKNIK OCH TEKNOLOGIERx Annan teknik0 (SwePub)2112 hsv//swe |
650 | 7 | a ENGINEERING AND TECHNOLOGYx Other Engineering and Technologies0 (SwePub)2112 hsv//eng |
653 | a Gamma Cameras | |
653 | a refractive index | |
653 | a Monte Carlo Transport | |
653 | a Spatial Resolution | |
653 | a scintillation crystal | |
700 | 1 | a Bettiol, Marcou Sapienza Univ Rome, Dept Mol Med, Rome, Italy.4 aut |
700 | 1 | a Bennati, Paolou KTH,Skolan för kemi, bioteknologi och hälsa (CBH),Sch Technol & Hlth, Stockholm, Sweden.4 aut0 (Swepub:kth)u1ua4ia4 |
700 | 1 | a Preziosi, Enricou Sapienza Univ Rome, Dept Mol Med, Rome, Italy.;Sapienza Univ Rome, SAIMLAL Dept, Morphofunct Sci, Rome, Italy.4 aut |
700 | 1 | a Fabbri, Andreau Univ Roma Tre, Ist Nazl Fis Nucl, Sez Roma 3, Rome, Italy.4 aut |
700 | 1 | a Scale, Raffaeleu Sapienza Univ Rome, Dept Mol Med, Rome, Italy.4 aut |
700 | 1 | a Pellegrini, Rosannau Sapienza Univ Rome, Dept Mol Med, Rome, Italy.4 aut |
700 | 1 | a Pani, Robertou Sapienza Univ Rome, Dept Medicosurg Sci & Biotechnol, Rome, Italy.4 aut |
710 | 2 | a Sapienza Univ Rome, Dept Mol Med, Rome, Italy.b Skolan för kemi, bioteknologi och hälsa (CBH)4 org |
773 | 0 | t 2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD)d : IEEEz 9781509016426 |
856 | 4 | u https://ieeexplore.ieee.org/xpl/mostRecentIssue.jsp?punumber=8062961y conference |
856 | 4 8 | u https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-242750 |
856 | 4 8 | u https://doi.org/10.1109/NSSMIC.2016.8069537 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.
Kopiera och spara länken för att återkomma till aktuell vy