SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Pellegrini Paolo)
 

Sökning: WFRF:(Pellegrini Paolo) > Monte Carlo Simulat...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00003704naa a2200445 4500
001oai:DiVA.org:kth-242750
003SwePub
008190219s2016 | |||||||||||000 ||eng|
024a https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-2427502 URI
024a https://doi.org/10.1109/NSSMIC.2016.80695372 DOI
040 a (SwePub)kth
041 a engb eng
042 9 SwePub
072 7a ref2 swepub-contenttype
072 7a kon2 swepub-publicationtype
100a Borrarzo, Cristianu Sapienza Univ Rome, Dept Mol Med, Rome, Italy.4 aut
2451 0a Monte Carlo Simulation to Evaluate Factors Affecting Imaging Performances of Compact Scintillation Gamma Camara
264 1b IEEE,c 2016
338 a print2 rdacarrier
500 a QC 20190219
520 a In recent years, a new generation of compact gamma cameras, based on monolithic scintillation crystals, has become increasingly widespread. The main advantages of small FoV gamma cameras with respect to the standard ones are high portability, low cost and low weight, allowing several clinical applications, from scintimammography to intraoperative tumor localization. In gamma cameras based on continuous scintillation crystals, intrinsic Spatial Resolution (SR) is mainly affected by two factors: scintillation light collection efficiency and overall crystal thickness. The first affects the counting statistics, the latter impacts on the light distribution width. To fully investigate the potentiality of these devices we took advantage of Monte Carlo simulations as a valuable tool to physically characterize the imaging systems and to establish a priori reference values. GEANT4 toolkit allows to completely describe the phenomenon of light emission and propagation through the media, providing control to all second-order factors existing in real systems. Results show clearly that SR is dependent on the number of photoelectrons produced and on the light spread. Furthermore, the role of refractive index has been unambiguously identified as an important factor affecting light collection and consequently SR.
650 7a TEKNIK OCH TEKNOLOGIERx Annan teknik0 (SwePub)2112 hsv//swe
650 7a ENGINEERING AND TECHNOLOGYx Other Engineering and Technologies0 (SwePub)2112 hsv//eng
653 a Gamma Cameras
653 a refractive index
653 a Monte Carlo Transport
653 a Spatial Resolution
653 a scintillation crystal
700a Bettiol, Marcou Sapienza Univ Rome, Dept Mol Med, Rome, Italy.4 aut
700a Bennati, Paolou KTH,Skolan för kemi, bioteknologi och hälsa (CBH),Sch Technol & Hlth, Stockholm, Sweden.4 aut0 (Swepub:kth)u1ua4ia4
700a Preziosi, Enricou Sapienza Univ Rome, Dept Mol Med, Rome, Italy.;Sapienza Univ Rome, SAIMLAL Dept, Morphofunct Sci, Rome, Italy.4 aut
700a Fabbri, Andreau Univ Roma Tre, Ist Nazl Fis Nucl, Sez Roma 3, Rome, Italy.4 aut
700a Scale, Raffaeleu Sapienza Univ Rome, Dept Mol Med, Rome, Italy.4 aut
700a Pellegrini, Rosannau Sapienza Univ Rome, Dept Mol Med, Rome, Italy.4 aut
700a Pani, Robertou Sapienza Univ Rome, Dept Medicosurg Sci & Biotechnol, Rome, Italy.4 aut
710a Sapienza Univ Rome, Dept Mol Med, Rome, Italy.b Skolan för kemi, bioteknologi och hälsa (CBH)4 org
773t 2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD)d : IEEEz 9781509016426
856u https://ieeexplore.ieee.org/xpl/mostRecentIssue.jsp?punumber=8062961y conference
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-242750
8564 8u https://doi.org/10.1109/NSSMIC.2016.8069537

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy