SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(van Ooij Pim)
 

Sökning: WFRF:(van Ooij Pim) > The Effect of Spati...

  • Cibis, MerihLinköpings universitet,Avdelningen för kardiovaskulär medicin,Medicinska fakulteten,Erasmus MC, Netherlands (författare)

The Effect of Spatial and Temporal Resolution of Cine Phase Contrast MRI on Wall Shear Stress and Oscillatory Shear Index Assessment

  • Artikel/kapitelEngelska2016

Förlag, utgivningsår, omfång ...

  • 2016-09-26
  • PUBLIC LIBRARY SCIENCE,2016
  • electronicrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:liu-132217
  • https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-132217URI
  • https://doi.org/10.1371/journal.pone.0163316DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Funding Agencies|Dutch Technology Foundation STW [Carisma] [11629]
  • Introduction Wall shear stress (WSS) and oscillatory shear index (OSI) are associated with atherosclerotic disease. Both parameters are derived from blood velocities, which can be measured with phase-contrast MRI (PC-MRI). Limitations in spatiotemporal resolution of PC-MRI are known to affect these measurements. Our aim was to investigate the effect of spatiotemporal resolution using a carotid artery phantom. Methods A carotid artery phantom was connected to a flow set-up supplying pulsatile flow. MRI measurement planes were placed at the common carotid artery (CCA) and internal carotid artery (ICA). Two-dimensional PC-MRI measurements were performed with thirty different spatiotemporal resolution settings. The MRI flow measurement was validated with ultrasound probe measurements. Mean flow, peak flow, flow waveform, WSS and OSI were compared for these spatiotemporal resolutions using regression analysis. The slopes of the regression lines were reported in %/mm and %/100ms. The distribution of low and high WSS and OSI was compared between different spatiotemporal resolutions. Results The mean PC-MRI CCA flow (2.5 +/- 0.2mL/s) agreed with the ultrasound probe measurements (2.7 +/- 0.02mL/s). Mean flow (mL/s) depended only on spatial resolution (CCA:-13%/ mm, ICA:-49%/mm). Peak flow (mL/s) depended on both spatial (CCA:-13%/mm, ICA:17%/ mm) and temporal resolution (CCA:-19%/100ms, ICA:-24%/100ms). Mean WSS (Pa) was in inverse relationship only with spatial resolution (CCA:-19%/mm, ICA:-33%/mm). OSI was dependent on spatial resolution for CCA (-26%/mm) and temporal resolution for ICA (-16%/100ms). The regions of low and high WSS and OSI matched for most of the spatiotemporal resolutions (CCA: 30/30, ICA: 28/30 cases for WSS; CCA: 23/30, ICA: 29/30 cases for OSI). Conclusion We show that both mean flow and mean WSS are independent of temporal resolution. Peak flow and OSI are dependent on both spatial and temporal resolution. However, the magnitude of mean and peak flow, WSS and OSI, and the spatial distribution of OSI and WSS did not exhibit a strong dependency on spatiotemporal resolution.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Potters, Wouter V.Academic Medical Centre, Netherlands (författare)
  • Gijsen, Frank J.Erasmus MC, Netherlands (författare)
  • Marquering, HenkAcademic Medical Centre, Netherlands; AMC, Netherlands (författare)
  • van Ooij, PimAcademic Medical Centre, Netherlands (författare)
  • I vanBave, EdAMC, Netherlands (författare)
  • Wentzel, Jolanda J.Erasmus MC, Netherlands (författare)
  • Nederveen, Aart J.Academic Medical Centre, Netherlands (författare)
  • Linköpings universitetAvdelningen för kardiovaskulär medicin (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:PLOS ONE: PUBLIC LIBRARY SCIENCE11:9, s. e0163316-1932-6203

Internetlänk

Hitta via bibliotek

  • PLOS ONE (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy