No adverse effects of submelt-annealed highly crosslinked polyethylene in cemented cups : an RSA study of 8 patients 10 years after surgery

Röhrl, Stephan M (author)
Department of Orthopaedics, Oslo University Hospital, Oslo
Nivbrant, Bo (author)
Perth Orthopaedic Institute, University of Western Australia, Perth, Australia
Nilsson, Kjell G (author)
Umeå universitet,Ortopedi
 (creator_code:org_t)
2012-01-17
2012
English.
In: Acta Orthopaedica. - : Informa Healthcare. - 1745-3674 .- 1745-3682. ; 83:2, s. 148-152
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Background and purpose Highly crosslinked polyethylene (PE) is in standard use worldwide. Differences in the crosslinking procedure may affect the clinical performance. Experimenatal data from retrieved cups have shown free radicals and excessive wear of annealed highly crosslinked PE. We have previously reported low wear and good clinical performance after 6 years with this implant, and now report on the 10-year results. Patients and methods In 8 patients, we measured wear of annealed highly crosslinked PE prospectively with radiostereometry after 10 years. Activity was assessed by UCLA activity score and a specifically designed activity score. Conventional radiographs were evaluated for osteolysis and clinical outcome by the Harris hip score (HHS). Results The mean (95% CI) proximal head penetration for highly crosslinked PE after 10 years was 0.07 (-0.015 to 0.153) mm, and the 3D wear was 0.2 (0.026 to 0.36) mm. Without creep, proximal head penetration was 0.02 (-0.026 to 0.066) mm and for 3D penetration was 0.016 (-0.47 to 0.08) mm. This represents an annual proximal wear of less than 2 mu m. All cups were clinically and radiographically stable but showed a tendency of increased rotation after 5 years. Interpretation Wear for annealed highly crosslinked PE is extremely low up to 10 years. Free radicals do not affect mechanical performance or lead to clinically adverse effects. Creep stops after the first 6 months after implantation. Highly crosslinked PE is a true competitor of hard-on-hard bearings.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Ortopedi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Orthopaedics (hsv//eng)

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Find more in SwePub

By the author/editor
Röhrl, Stephan M
Nivbrant, Bo
Nilsson, Kjell G
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Orthopaedics
Articles in the publication
Acta Orthopaedic ...
By the university
Umeå University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view