SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

L773:0035 8711 OR L773:1365 2966
 

Sökning: L773:0035 8711 OR L773:1365 2966 > Accurate laboratory...

Accurate laboratory ultraviolet wavelengths for quasar absorption-line constraints on varying fundamental constants

Aldenius, Maria (författare)
Lund University,Lunds universitet,Astronomi - Genomgår omorganisation,Institutionen för astronomi och teoretisk fysik - Genomgår omorganisation,Naturvetenskapliga fakulteten,Lund Observatory - Undergoing reorganization,Department of Astronomy and Theoretical Physics - Undergoing reorganization,Faculty of Science
Johansson, Sveneric (författare)
Lund University,Lunds universitet,Astronomi - Genomgår omorganisation,Institutionen för astronomi och teoretisk fysik - Genomgår omorganisation,Naturvetenskapliga fakulteten,Lund Observatory - Undergoing reorganization,Department of Astronomy and Theoretical Physics - Undergoing reorganization,Faculty of Science
Murphy, M. T. (författare)
 (creator_code:org_t)
Oxford University Press (OUP), 2006
2006
Engelska.
Ingår i: Monthly Notices of the Royal Astronomical Society. - : Oxford University Press (OUP). - 1365-2966 .- 0035-8711. ; 370:1, s. 444-452
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The most precise method of investigating possible space-time variations of the fine-structure constant, alpha equivalent to (1/hc)(e(2)/4 pi epsilon(0)), using high-redshift quasar absorption lines is the many-multiplet (MM) method. For reliable results this method requires very accurate relative laboratory wavelengths for a number of UV resonance transitions from several different ionic species. For this purpose laboratory wavelengths and wavenumbers of 23 UV lines from Mg I, Mg II, Ti II, Cr II, Mn II, Fe II and Zn II have been measured using high-resolution Fourier transform (FT) spectrometry. The spectra of the different ions (except for one Fe II line, one Mg I line and the Ti II lines) are all measured simultaneously in the same FT spectrometry recording by using a composite hollow cathode as a light source. This decreases the relative uncertainties of all the wavelengths. In addition to any measurement uncertainty, the wavelength uncertainty is determined by that of the Ar II calibration lines, by possible pressure shifts and by illumination effects. The absolute wavenumbers have uncertainties of typically +/- 0.001 -+/- 0.002 cm(-1) (Delta lambda approximate to 0.06-0.1 m angstrom at 2500 angstrom), while the relative wavenumbers for strong, symmetric lines in the same spectral recording have uncertainties of +/- 0.0005 cm(-1) (Delta lambda approximate to 0.03 m angstrom at 2500 angstrom) or better, depending mostly on uncertainties in the line-fitting procedure. This high relative precision greatly reduces the potential for systematic effects in the MM method, while the new Ti II measurements now allow these transitions to be used in MM analyses.

Ämnesord

NATURVETENSKAP  -- Fysik -- Astronomi, astrofysik och kosmologi (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Astronomy, Astrophysics and Cosmology (hsv//eng)

Nyckelord

quasars : absorption lines
spectroscopic
techniques
methods : laboratory
atomic data
line : profiles
ultraviolet : general

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Aldenius, Maria
Johansson, Svene ...
Murphy, M. T.
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Fysik
och Astronomi astrof ...
Artiklar i publikationen
Monthly Notices ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy