SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:0730 725X OR L773:1873 5894
 

Sökning: L773:0730 725X OR L773:1873 5894 > (1986-1989) > A method for MR qua...

A method for MR quantification of flow velocities in blood and CSF using interleaved gradient-echo pulse sequences

Ståhlberg, Freddy (författare)
Lund University,Lunds universitet
Mogelvang, Jens (författare)
Hvidovre Hospital
Thomsen, Carsten (författare)
Hvidovre Hospital
visa fler...
Nordell, Bo (författare)
Karolinska University Hospital
Stubgaard, Max (författare)
Hvidovre Hospital
Ericsson, Anders (författare)
Uppsala University Hospital
Sperber, Göran (författare)
Uppsala University Hospital
Greitz, Dan (författare)
Karolinska University Hospital
Larsson, Henrik (författare)
Hvidovre Hospital
Henriksen, Ole (författare)
Hvidovre Hospital
Persson, Bertil (författare)
Lund University,Lunds universitet
visa färre...
 (creator_code:org_t)
1989
1989
Engelska 13 s.
Ingår i: Magnetic Resonance Imaging. - 0730-725X. ; 7:6, s. 655-667
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The aim of this study was to establish a rapid method for in vivo quantification of a large range of flow velocities using phase information. A basic gradient-echo sequence was constructed, in which flow was encoded along the slice selection direction by variation of the amplitude of a bipolar gradient without changes in sequence timings. The influence of field inhomogeneities and eddy currents was studied in a 1.5 T scanner. From the basic sequence, interleaved sequences for calibration and in vivo flow determination were constructed, and flow information was obtained by pairwise subtraction of velocity-encoded from velocity non-encoded phase images. Calibration was performed in a nongated mode using flow phantoms, and the results were compared with theoretically calculated encoding efficiencies. In vivo flow was studied in healthy volunteers in three different areas using cardiac gating; central blood flow in the great thoracic vessels, peripheral blood flow in the popliteal vessels, and flow of cerebrospinal fluid (CSF) in the cerebral aqueduct. The results show good agreement with results obtained with other techniques. The proposed method for flow determination was shown to be rapid and flexible, and we thus conclude that it seems well suited for routine clinical MR examinations.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Nyckelord

Blood
CSF
Flow
Gradient echo
MR
Phase image
Quantification

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy