Bioimpedance technology for detection of thoracic injury

Buendia, Ruben, 1982 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Candefjord, Stefan, 1981 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Sanchez, B. (författare)
visa fler...
Granhed, Hans (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för kirurgi,Institute of Clinical Sciences, Department of Surgery
Sjöqvist, Bengt-Arne, 1952 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Örtenwall, Per, 1951 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för kirurgi,Institute of Clinical Sciences, Department of Surgery
Caragounis, Eva Corina (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för kirurgi,Institute of Clinical Sciences, Department of Surgery
visa färre...
 (creator_code:org_t)
2017-10-31
2017
Engelska.
Ingår i: Physiological Measurement. - : IOP Publishing. - 0967-3334 .- 1361-6579. ; 38:11, s. 2000-2014
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objective: Thoracic trauma is one of the most common and lethal types of injury, causing over a quarter of traumatic deaths. Severe thoracic injuries are often occult and difficult to diagnose in the field. There is a need for a point-of-care diagnostic device for severe thoracic injuries in the prehospital setting. Electrical bioimpedance (EBI) is non-invasive, portable, rapid and easy to use technology that can provide objective and quantitative diagnostic information for the prehospital environment. Here, we evaluated the performance of EBI to detect thoracic injuries. Approach: In this open study, EBI resistance (R), reactance (X) and phase angle (PA) of both sides of the thorax were measured at 50 kHz on patients suffering from thoracic injuries (n = 20). In parallel, a control group consisting of healthy subjects (n = 20) was recruited. A diagnostic mathematical algorithm, fed with input parameters derived from EBI data, was designed to differentiate patients from healthy controls. Main results: Ratios between the X and PA measurements of both sides of the thorax were significantly different (p < 0.05) between healthy volunteers and patients with left-and right-sided injuries. The diagnostic algorithm achieved a performance evaluated by leave-one-out cross-validation analysis and derived area under the receiver operating characteristic curve of 0.88. Significance: A diagnostic algorithm that accurately discriminates between patients suffering thoracic injuries and healthy subjects was designed using EBI technology. A larger, prospective and blinded study is thus warranted to validate the feasibility of EBI technology as a prehospital tool.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Nyckelord

bioimpedance
thoracic injuries
prehospital care
diagnostics
trauma
injury prevention
bioelectrical-impedance
body-composition
localized bioimpedance
skin
temperature
muscle injury
global burden
trauma-center
mortality
deaths
time
Biophysics
Engineering
Physiology
trauma

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy