SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Abdollahi Sara)
 

Sökning: WFRF:(Abdollahi Sara) > Surface guided 3DCR...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00004158naa a2200433 4500
001oai:lup.lub.lu.se:2aa1a694-00f3-4b85-a948-5b956cefdf4a
003SwePub
008221205s2022 | |||||||||||000 ||eng|
024a https://lup.lub.lu.se/record/2aa1a694-00f3-4b85-a948-5b956cefdf4a2 URI
024a https://doi.org/10.5603/rpOr.a2022.01032 DOI
040 a (SwePub)lu
041 a engb eng
042 9 SwePub
072 7a art2 swepub-publicationtype
072 7a ref2 swepub-contenttype
100a Abdollahi, Sarau Ferdowsi University of Mashhad,Reza Radiotherapy and Oncology Center4 aut
2451 0a Surface guided 3DCRT in deep-inspiration breath-hold for left sided breast cancer radiotherapy : implementation and first clinical experience in Iran
264 1c 2022
300 a 16 s.
520 a Background: The aim of the study is to evaluate the overall accuracy of the surface-guided radiotherapy (SGRT) workflow through a comprehensive commissioning and quality assurance procedures and assess the potential benefits of deep-inspiration breath-hold (DIBH) radiotherapy as a cardiac and lung dose reduction approach for left-sided breast cancer irradiation. Materials and methods: Accuracy and reproducibility of the optical surface scanner used for DIBH treatment were evaluated using different phantoms. Patient positioning accuracy and reproducibility of DIBH treatment were evaluated. Twenty patients were studied for treatment plan quality in target dose coverage and healthy organ sparing for the two different treatment techniques. Results: Reproducibility tests for the surface scanner showed good stability within 1 mm in all directions. The maximum position variation between applied shifts on the couch and the scanner measured offsets is 1 mm in all directions. The clinical study of 200 fractions showed good agreement between the surface scanner and portal imaging with the isocenter position deviation of less than 3 mm in each lateral, longitudinal, and vertical direction. The standard deviation of the DIBH level showed a value of < 2 mm during all evaluated DIBHs. Compared to the free breathing (FB) technique, DIBH showed significant reduction of 48% for heart mean dose, 43% for heart V25, and 20% for ipsilateral lung V20. Conclusion: Surface-guided radiotherapy can be regarded as an accurate tool for patient positioning and monitoring in breast radiotherapy. DIBH treatment are considered to be effective techniques in heart and ipsilateral lung dose reductions for left breast radiotherapy.
650 7a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Cancer och onkologi0 (SwePub)302032 hsv//swe
650 7a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Cancer and Oncology0 (SwePub)302032 hsv//eng
653 a Cardiac sparing
653 a Dibh
653 a Motion management
653 a Surface imaging
700a Yazdi, Mohammad Hadi Hadizadehu Ferdowsi University of Mashhad4 aut
700a Mowlavi, Ali Asgharu Ferdowsi University of Mashhad4 aut
700a Ceberg, Sofieu Lund University,Lunds universitet,Radiotherapy Physics,Forskargrupper vid Lunds universitet,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Lund University Research Groups,LUCC: Lund University Cancer Centre,Other Strong Research Environments4 aut0 (Swepub:lu)med-sem
700a Aznar, Marianne Camilleu University of Manchester4 aut
700a Tabrizi, Fatemeh Varshoeeu Reza Radiotherapy and Oncology Center4 aut
700a Salek, Rohamu Reza Radiotherapy and Oncology Center,Mashhad University of Medical Sciences4 aut
700a Ghodsi, Alirezau Hakim Sabzevari University4 aut
700a Jamali, Faridehu Reza Radiotherapy and Oncology Center4 aut
710a Ferdowsi University of Mashhadb Reza Radiotherapy and Oncology Center4 org
773t Reports of Practical Oncology and Radiotherapyg 27:5, s. 881-896q 27:5<881-896x 1507-1367
856u http://dx.doi.org/10.5603/rpOr.a2022.0103y FULLTEXT
8564 8u https://lup.lub.lu.se/record/2aa1a694-00f3-4b85-a948-5b956cefdf4a
8564 8u https://doi.org/10.5603/rpOr.a2022.0103

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy