Sökning: WFRF:(Blankenstein M. A.) >
A worldwide multice...
A worldwide multicentre comparison of assays for cerebrospinal fluid biomarkers in Alzheimer's disease.
-
Verwey, N A (författare)
-
van der Flier, W M (författare)
-
- Blennow, Kaj, 1958 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för psykiatri och neurokemi,Institute of Neuroscience and Physiology, Department of Psychiatry and Neurochemistry
-
visa fler...
-
Clark, C (författare)
-
Sokolow, S (författare)
-
De Deyn, P P (författare)
-
Galasko, D (författare)
-
Hampel, H (författare)
-
Hartmann, T (författare)
-
Kapaki, E (författare)
-
- Lannfelt, Lars (författare)
- Uppsala universitet,Geriatrik
-
Mehta, P D (författare)
-
Parnetti, L (författare)
-
Petzold, A (författare)
-
Pirttila, T (författare)
-
Saleh, L (författare)
-
Skinningsrud, A (författare)
-
Swieten, J C V (författare)
-
Verbeek, M M (författare)
-
Wiltfang, J (författare)
-
Younkin, S (författare)
-
Scheltens, P (författare)
-
Blankenstein, M A (författare)
-
visa färre...
-
(creator_code:org_t)
- 2009-04-02
- 2009
- Engelska.
-
Ingår i: Annals of clinical biochemistry. - : SAGE Publications. - 0004-5632 .- 1758-1001. ; 46:Pt 3, s. 235-40
- Relaterad länk:
-
https://gup.ub.gu.se...
-
visa fler...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- BACKGROUND: Different cerebrospinal fluid (CSF) amyloid-beta 1-42 (Abeta(1-42)), total Tau (Tau) and Tau phosphorylated at threonine 181 (P-Tau) levels are reported, but currently there is a lack of quality control programmes. The aim of this study was to compare the measurements of these CSF biomarkers, between and within centres. METHODS: Three CSF-pool samples were distributed to 13 laboratories in 2004 and the same samples were again distributed to 18 laboratories in 2008. In 2004 six laboratories measured Abeta(1-42), Tau and P-Tau and seven laboratories measured one or two of these marker(s) by enzyme-linked immunosorbent assays (ELISAs). In 2008, 12 laboratories measured all three markers, three laboratories measured one or two marker(s) by ELISAs and three laboratories measured the markers by Luminex. RESULTS: In 2004, the ELISA intercentre coefficients of variance (interCV) were 31%, 21% and 13% for Abeta(1-42), Tau and P-Tau, respectively. These were 37%, 16% and 15%, respectively, in 2008. When we restricted the analysis to the Innotest (N = 13) for Abeta(1-42), lower interCV were calculated (22%). The centres that participated in both years (N = 9) showed interCVs of 21%, 15% and 9% and intra-centre coefficients (intraCV) of variance of 25%,18% and 7% in 2008. CONCLUSIONS: The highest variability was found for Abeta(1-42). The variabilities for Tau and P-Tau were lower in both years. The centres that participated in both years showed a high intraCV comparable to their interCV, indicating that there is not only a high variation between but also within centres. Besides a uniform standardization of (pre)analytical procedures, the same assay should be used to decrease the inter/intracentre variation.
Nyckelord
- Alzheimer Disease
- cerebrospinal fluid
- Amyloid beta-Protein
- cerebrospinal fluid
- Biological Assay
- methods
- Enzyme-Linked Immunosorbent Assay
- methods
- Humans
- Reproducibility of Results
- tau Proteins
- cerebrospinal fluid
- MEDICINE
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Verwey, N A
-
van der Flier, W ...
-
Blennow, Kaj, 19 ...
-
Clark, C
-
Sokolow, S
-
De Deyn, P P
-
visa fler...
-
Galasko, D
-
Hampel, H
-
Hartmann, T
-
Kapaki, E
-
Lannfelt, Lars
-
Mehta, P D
-
Parnetti, L
-
Petzold, A
-
Pirttila, T
-
Saleh, L
-
Skinningsrud, A
-
Swieten, J C V
-
Verbeek, M M
-
Wiltfang, J
-
Younkin, S
-
Scheltens, P
-
Blankenstein, M ...
-
visa färre...
- Artiklar i publikationen
-
Annals of clinic ...
-
Annals of Clinic ...
- Av lärosätet
-
Göteborgs universitet
-
Uppsala universitet