SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Lammertsma Adriaan A.)
 

Sökning: WFRF:(Lammertsma Adriaan A.) > Parametric Methods ...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00003319naa a2200481 4500
001oai:DiVA.org:uu-317725
003SwePub
008170317s2017 | |||||||||||000 ||eng|
024a https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-3177252 URI
024a https://doi.org/10.2967/jnumed.116.1787072 DOI
040 a (SwePub)uu
041 a engb eng
042 9 SwePub
072 7a ref2 swepub-contenttype
072 7a art2 swepub-publicationtype
100a Mansor, Syahir4 aut
2451 0a Parametric Methods for Dynamic (11)C-Phenytoin PET Studies.
264 c 2016-09-22
264 1b Society of Nuclear Medicine,c 2017
338 a print2 rdacarrier
520 a In this study, the performance of various methods for generating quantitative parametric images of dynamic (11)C-phenytoin PET studies was evaluated. Methods: Double-baseline 60-min dynamic (11)C-phenytoin PET studies, including online arterial sampling, were acquired for 6 healthy subjects. Parametric images were generated using Logan plot analysis, a basis function method, and spectral analysis. Parametric distribution volume (VT) and influx rate (K1) were compared with those obtained from nonlinear regression analysis of time-activity curves. In addition, global and regional test-retest (TRT) variability was determined for parametric K1 and VT values. Results: Biases in VT observed with all parametric methods were less than 5%. For K1, spectral analysis showed a negative bias of 16%. The mean TRT variabilities of VT and K1 were less than 10% for all methods. Shortening the scan duration to 45 min provided similar VT and K1 with comparable TRT performance compared with 60-min data. Conclusion: Among the various parametric methods tested, the basis function method provided parametric VT and K1 values with the least bias compared with nonlinear regression data and showed TRT variabilities lower than 5%, also for smaller volume-of-interest sizes (i.e., higher noise levels) and shorter scan duration.
650 7a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Radiologi och bildbehandling0 (SwePub)302082 hsv//swe
650 7a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Radiology, Nuclear Medicine and Medical Imaging0 (SwePub)302082 hsv//eng
653 a 11C-phenytoin
653 a PET quantification
653 a parametric kinetic modeling
653 a test-retest variability
700a Yaqub, Maqsood4 aut
700a Boellaard, Ronald4 aut
700a Froklage, Femke E4 aut
700a de Vries, Anke4 aut
700a Bakker, Esther D M4 aut
700a Voskuyl, Rob A4 aut
700a Eriksson, Jonasu Uppsala universitet,Avdelningen för Molekylär Avbildning4 aut0 (Swepub:uu)joeri542
700a Schwarte, Lothar A4 aut
700a Verbeek, Joost4 aut
700a Windhorst, Albert D4 aut
700a Lammertsma, Adriaan A4 aut
710a Uppsala universitetb Avdelningen för Molekylär Avbildning4 org
773t Journal of Nuclear Medicined : Society of Nuclear Medicineg 58:3, s. 479-483q 58:3<479-483x 0161-5505x 1535-5667x 2159-662X
856u http://jnm.snmjournals.org/content/58/3/479.full.pdf
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-317725
8564 8u https://doi.org/10.2967/jnumed.116.178707

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy