SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Lincoln Per 1958)
 

Sökning: WFRF:(Lincoln Per 1958) > Vesicle size-depend...

Vesicle size-dependent translocation of penetratin analogs across lipid membranes

Persson, Daniel, 1972 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Thoren, Per, 1972 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Esbjörner Winters, Elin, 1978 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa fler...
Goksör, Mattias, 1975 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för fysik (GU),Department of Physics (GU)
Lincoln, Per, 1958 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Nordén, Bengt, 1945 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa färre...
 (creator_code:org_t)
Elsevier BV, 2004
2004
Engelska.
Ingår i: Biochimica et Biophysica Acta - Biomembranes. - : Elsevier BV. - 1879-2642 .- 0005-2736. ; 1665:1-2, s. 142-155
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The recent discoveries of serious artifacts associated with the use of cell fixation in studies of the cellular uptake of cell-penetrating peptides (CPPs) have prompted a reevaluation of the current understanding of peptide-mediated cellular delivery. Following a report on the differential cellular uptake of a number of penetratin analogs in unfixed cells, we here investigate their membrane translocation abilities in large and giant unilamellar vesicles (LUVs and GUVs, respectively). Surprisingly, in contrast to the behavior in living cells, all peptides readily entered the giant vesicles ( > 1 μm) as proved by confocal microscopy, while none of them could cross the membranes of LUVs (100 nm). For determination of the location of the peptides in the LUVs, a new concept was introduced, based on sensitive resonance energy transfer (RET) measurements of the enhanced fluorescence of acceptor fluorophores present solely in the inner leaflet. An easily adopted method to prepare such asymmetrically labeled liposomes is described. The membrane insertion depths of the tryptophan moieties of the peptides were determined by use of brominated lipids and found to be very similar for all of the peptides studied. We also demonstrate that infrared spectroscopy on the lipid carbonyl stretch vibration peak is a convenient technique to determine phospholipid concentration. © 2004 Elsevier B.V. All rights reserved.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Medicinsk bioteknologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Medical Biotechnology (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy