Sökning: hsv:(ENGINEERING AND TECHNOLOGY) hsv:(Medical Engineering) hsv:(Medical Materials) > (1996-1999) > Tissue reactions to...
Fältnamn | Indikatorer | Metadata |
---|---|---|
000 | 02833naa a2200325 4500 | |
001 | oai:lup.lub.lu.se:3de78707-7b54-4167-9d3f-dfac306f37a3 | |
003 | SwePub | |
008 | 160401s1999 | |||||||||||000 ||eng| | |
024 | 7 | a https://lup.lub.lu.se/record/11142762 URI |
024 | 7 | a https://doi.org/10.1023/A:10089648191012 DOI |
040 | a (SwePub)lu | |
041 | a engb eng | |
042 | 9 SwePub | |
072 | 7 | a art2 swepub-publicationtype |
072 | 7 | a ref2 swepub-contenttype |
100 | 1 | a Rosengren, Agnetau Lund University,Lunds universitet,Institutionen för experimentell medicinsk vetenskap,Medicinska fakulteten,Department of Experimental Medical Science,Faculty of Medicine4 aut0 (Swepub:lu)kir-aro |
245 | 1 0 | a Tissue reactions to polyethylene implants with different surface topography |
264 | 1 | c 1999 |
520 | a This study investigates the importance of implant surface topography on soft tissue response. The tissue response in the rat abdominal wall to discs of low density polyethylene with smooth to coarse surfaces was evaluated after one, six or 12 weeks. Capsule thickness and immunohistochemical quantification of monocytes-macrophages were used as measures. The macrophage specific antibody ED1 was used for identification of newly recruited macrophages and the ED2 antibody for the mature tissue macrophages. The smoother surfaces gave a thicker capsule than the rougher surfaces, and at one week also larger total numbers of cells and ED1 positive macrophages at interface. The capsule thickness increased over time for the smooth and intermediate surface topographies. In contrast, the cell numbers generally decreased over time. In conclusion, a coarse surface elicited lesser tissue reaction compared with a smooth surface. | |
650 | 7 | a TEKNIK OCH TEKNOLOGIERx Medicinteknikx Medicinsk material- och protesteknik0 (SwePub)206022 hsv//swe |
650 | 7 | a ENGINEERING AND TECHNOLOGYx Medical Engineeringx Medical Materials0 (SwePub)206022 hsv//eng |
700 | 1 | a Bjursten, Lars Magnusu Lund University,Lunds universitet,Institutionen för experimentell medicinsk vetenskap,Medicinska fakulteten,Department of Experimental Medical Science,Faculty of Medicine4 aut0 (Swepub:lu)exp-lbj |
700 | 1 | a Danielsen, Nilsu Lund University,Lunds universitet,Neurala gränsytor,Forskargrupper vid Lunds universitet,Neural Interfaces,Lund University Research Groups4 aut0 (Swepub:lu)mphy-nda |
700 | 1 | a Persson, H4 aut |
700 | 1 | a Kober, M4 aut |
710 | 2 | a Institutionen för experimentell medicinsk vetenskapb Medicinska fakulteten4 org |
773 | 0 | t Journal of Materials Science: Materials in Medicineg 10:2, s. 75-82q 10:2<75-82x 1573-4838 |
856 | 4 | u http://dx.doi.org/10.1023/A:1008964819101y FULLTEXT |
856 | 4 8 | u https://lup.lub.lu.se/record/1114276 |
856 | 4 8 | u https://doi.org/10.1023/A:1008964819101 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.