SwePub
Sök i LIBRIS databas

  Utökad sökning

hsv:(ENGINEERING AND TECHNOLOGY) hsv:(Medical Engineering) hsv:(Medical Materials)
 

Sökning: hsv:(ENGINEERING AND TECHNOLOGY) hsv:(Medical Engineering) hsv:(Medical Materials) > (1996-1999) > Tissue reactions to...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00002833naa a2200325 4500
001oai:lup.lub.lu.se:3de78707-7b54-4167-9d3f-dfac306f37a3
003SwePub
008160401s1999 | |||||||||||000 ||eng|
024a https://lup.lub.lu.se/record/11142762 URI
024a https://doi.org/10.1023/A:10089648191012 DOI
040 a (SwePub)lu
041 a engb eng
042 9 SwePub
072 7a art2 swepub-publicationtype
072 7a ref2 swepub-contenttype
100a Rosengren, Agnetau Lund University,Lunds universitet,Institutionen för experimentell medicinsk vetenskap,Medicinska fakulteten,Department of Experimental Medical Science,Faculty of Medicine4 aut0 (Swepub:lu)kir-aro
2451 0a Tissue reactions to polyethylene implants with different surface topography
264 1c 1999
520 a This study investigates the importance of implant surface topography on soft tissue response. The tissue response in the rat abdominal wall to discs of low density polyethylene with smooth to coarse surfaces was evaluated after one, six or 12 weeks. Capsule thickness and immunohistochemical quantification of monocytes-macrophages were used as measures. The macrophage specific antibody ED1 was used for identification of newly recruited macrophages and the ED2 antibody for the mature tissue macrophages. The smoother surfaces gave a thicker capsule than the rougher surfaces, and at one week also larger total numbers of cells and ED1 positive macrophages at interface. The capsule thickness increased over time for the smooth and intermediate surface topographies. In contrast, the cell numbers generally decreased over time. In conclusion, a coarse surface elicited lesser tissue reaction compared with a smooth surface.
650 7a TEKNIK OCH TEKNOLOGIERx Medicinteknikx Medicinsk material- och protesteknik0 (SwePub)206022 hsv//swe
650 7a ENGINEERING AND TECHNOLOGYx Medical Engineeringx Medical Materials0 (SwePub)206022 hsv//eng
700a Bjursten, Lars Magnusu Lund University,Lunds universitet,Institutionen för experimentell medicinsk vetenskap,Medicinska fakulteten,Department of Experimental Medical Science,Faculty of Medicine4 aut0 (Swepub:lu)exp-lbj
700a Danielsen, Nilsu Lund University,Lunds universitet,Neurala gränsytor,Forskargrupper vid Lunds universitet,Neural Interfaces,Lund University Research Groups4 aut0 (Swepub:lu)mphy-nda
700a Persson, H4 aut
700a Kober, M4 aut
710a Institutionen för experimentell medicinsk vetenskapb Medicinska fakulteten4 org
773t Journal of Materials Science: Materials in Medicineg 10:2, s. 75-82q 10:2<75-82x 1573-4838
856u http://dx.doi.org/10.1023/A:1008964819101y FULLTEXT
8564 8u https://lup.lub.lu.se/record/1114276
8564 8u https://doi.org/10.1023/A:1008964819101

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy