Sökning: (L773:1522 2586) srt2:(1995-1999) >
Use of k-space segm...
Use of k-space segmentation in MR velocity mapping for rapid quantification of CSF flow
-
- Ståhlberg, Freddy (författare)
- Lund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
-
Nitz, Wolfgang (författare)
-
- Nilsson, Christer (författare)
- Lund University,Lunds universitet,Psykiatri, Lund,Sektion IV,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Psychiatry (Lund),Section IV,Department of Clinical Sciences, Lund,Faculty of Medicine
-
visa fler...
-
- Holtås, Stig (författare)
- Lund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
-
visa färre...
-
(creator_code:org_t)
- Wiley, 1997
- 1997
- Engelska.
-
Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley. - 1522-2586 .- 1053-1807. ; 7:6, s. 972-978
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- In this work, a k-space segmentation technique for quantitative studies of pulsatile cerebrospinal fluid (CSF) flow is suggested. Three k-space lines are sampled for each of two interleaved gradient-echo sequences (velocity-compensated and velocity-encoded) within each repetition interval. Nine cardiac phases are obtained at a heart rate of 60 bpm with maintained nominal resolution and a factor of 3 in reduction of acquisition time relative to our conventional nonsegmented flow quantification protocol. Segmented and conventional sequences were compared in phantoms, in healthy volunteers, and in two patients with clinically suspected normal pressure hydrocephalus. Good agreement between flow curves obtained with the two sequences was demonstrated in vitro as well as in vivo. A slight underestimation of flow values in volunteers was attributed to data filtering when using the segmented sequence. Because the CSF circulation is complex and tightly connected to the vascular circulation, specific clinical applications may require flow studies at multiple positions and with different velocity encoding. In such cases, the proposed sequence can be used to gain time, but alternatively, the segmentation technique can be used to further increase spatial resolution within reasonable examination times.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
Nyckelord
- MRI
- Flow
- Quantification
- Cerebrospinal fluid
- Fast imaging
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas