SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:0168 583X
 

Sökning: L773:0168 583X > Structural characte...

Intracavity optogalvanic spectroscopy: Is there any evidence of a radiocarbon signal?

Persson, Anders (författare)
Salehpour, Mehran (författare)
 (utgivare)
 (utgivare)
visa fler...
 (medarbetare)
 (medarbetare)
visa färre...
2015
2015
Engelska.
Ingår i: Nuclear Instruments and Methods in Physics Research Section B. - 0168-583X. ; 361, 8-12
  • swepub:Mat__t
Abstract Ämnesord
Stäng  
  • In 2008, the first report of an ultrasensitive method for ro-vibrational spectrometry of radiocarbon dioxide was published. The method, called intracavity optogalvanic spectroscopy (ICOGS), claimed a sensitivity and limit-of-detection comparable to accelerator mass spectroscopy. ICOGS was claimed to utilize the isotope-dependent ro-vibrational absorption lines of carbon dioxide in the infrared spectrum. In order to facilitate unambiguous detection of radiocarbon, the sample was placed inside the cavity of a radiocarbon dioxide laser. This intracavity approach was claimed to increase the sensitivity by seven orders of magnitude compared with traditional optogalvanic methods. However, despite the methodical and thorough efforts of several research groups worldwide, these claims have not been possible to reproduce. Instead, we have previously reported serious deviations from the original results, where we found that ICOGS suffers from considerable problems with the stability and reproducibility of the optogalvanic signal, and that misinterpretations of these uncertainties likely are the explanation for the claimed sensitivity in the first reports. Having identified the stability and reproducibility of the detection as major concerns, we decided to improve the setup by with state-of-the-art plasma source technology. Deploying a custom-made stripline split-ring resonator optogalvanic detector, we have now investigated the applicability of ICOGS to radiocarbon detection even further. Measurements have been made with a wide range of parameters including different gas mixtures at various pressures and wavelengths. We have also conducted measurements with gas flowing through the sample cell to investigate the effect of plasma induced decomposition of the sample. Still, we have seen no indications of a significant radiocarbon signal in a concentration range between 0.29 Modern and 9.7 Modern, i.e., the range of interest to the radiocarbon community. Hence, our conclusions after four years of working in this field, is that ICOGS is not a viable method for radiocarbon detection. 

Ämnesord

Natural Sciences  (hsv)
Physical Sciences  (hsv)
Atom and Molecular Physics and Optics  (hsv)
Naturvetenskap  (hsv)
Fysik  (hsv)
Atom- och molekylfysik och optik  (hsv)
Engineering and Technology  (hsv)
Electrical Engineering, Electronic Engineering, Information Engineering  (hsv)
Teknik och teknologier  (hsv)
Elektroteknik och elektronik  (hsv)
Teknisk fysik med inriktning mot mikrosystemteknik  (uu)
Engineering Science with specialization in Microsystems Technology  (uu)
Fysik med inriktning mot tillämpad kärnfysik  (uu)
Physics with specialization in Applied Nuclear Physics  (uu)

Nyckelord

Intracavity optogalvanic spectroscopy; Split-ring resonator; Radiocarbon; Cavity-enhanced; Infrared spectroscopy

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Azevedo, GD
Ridgway, MC
Yu, KM
Glover, Chris
Foran, GJ
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Fysik
Artiklar i publikationen
Nuclear Instrume ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy