Sökning: WFRF:(Eikenboom J. C. J.) >
Validation of a rap...
Validation of a rapid test (VWF-LIA) for the quantitative determination of von Willebrand factor antigen in type 1 von Willebrand disease diagnosis within the European multicenter study MCMDM-1VWD
-
Castaman, G. (författare)
-
Tosetto, A. (författare)
-
Cappelletti, A. (författare)
-
visa fler...
-
Goodeve, A. (författare)
-
Federici, A. B. (författare)
-
Batlle, J. (författare)
-
Meyer, D. (författare)
-
Goudemand, J. (författare)
-
Eikenboom, J. C. J. (författare)
-
Schneppenheim, R. (författare)
-
Budde, U. (författare)
-
Ingerslev, J. (författare)
-
- Lethagen, Stefan (författare)
- Lund University,Lunds universitet,Institutionen för kliniska vetenskaper, Malmö,Medicinska fakulteten,Department of Clinical Sciences, Malmö,Faculty of Medicine
-
Hill, F. (författare)
-
Peake, I. R. (författare)
-
Rodeghiero, F. (författare)
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 2010
- 2010
- Engelska.
-
Ingår i: Thrombosis Research. - : Elsevier BV. - 1879-2472 .- 0049-3848. ; 126:3, s. 227-231
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Background: Accurate measurement of von Willebrand factor (VWF) is a critical requirement for the diagnosis of von Willebrand disease (VWD). Aim of the study: To evaluate the diagnostic efficiency of a rapid quantitative test for the measurement of VWF antigen (VWF:Ag) in type 1 VWD. Patients and methods: VWF: Ag was measured with an ELISA in a robotic instrument, as a reference method, and with a fully automated latex-immunoassay (LIA) on an ACL 9000 analyser in 1,716 subjects enrolled within the Molecular and Clinical Markers for Diagnosis and Management of Type 1 von Willebrand Disease (MCMDM-1VWD) Study. Among these subjects, 1,049 were healthy controls, 281 healthy family members and 386 affected members from 127 European families with type 1 VWD. Results: The assay linearity range was 10-125 IU/dL for LIA (R-2 = 0.99) and 5-133 IU/dL for ELISA (R-2 = 0.99). The inter-assay CV for low VWF levels (similar to 30 IU/dL) was 2% for the LIA test and 8.7 % for ELISA. The sensitivity for detection of type 1 VWD affected members was 86% and the specificity 91% for LIA, 87% and 90% for ELISA. A receiver-operator (ROC) analysis disclosed only a marginal difference between the two tests, LIA having a slightly greater area under the curve (0.94 vs. 0.93, p = 0.03). Conclusion: VWF: Ag LIA compared well to standard ELISA in this large population of patients and controls, showing better CV. However the lower detection limit for the VWF: Ag LIA compared to the VWF: Ag ELISA means that the LIA assay is less good at discriminating between type 3 VWD and moderate type 1 VWD. (C) 2010 Elsevier Ltd. All rights reserved.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Kardiologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)
Nyckelord
- disorders
- Inherited bleeding
- von Willebrand factor
- von Willebrand disease
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Castaman, G.
-
Tosetto, A.
-
Cappelletti, A.
-
Goodeve, A.
-
Federici, A. B.
-
Batlle, J.
-
visa fler...
-
Meyer, D.
-
Goudemand, J.
-
Eikenboom, J. C. ...
-
Schneppenheim, R ...
-
Budde, U.
-
Ingerslev, J.
-
Lethagen, Stefan
-
Hill, F.
-
Peake, I. R.
-
Rodeghiero, F.
-
visa färre...
- Om ämnet
-
- MEDICIN OCH HÄLSOVETENSKAP
-
MEDICIN OCH HÄLS ...
-
och Klinisk medicin
-
och Kardiologi
- Artiklar i publikationen
-
Thrombosis Resea ...
- Av lärosätet
-
Lunds universitet