Sökning: WFRF:(Ghilardi G) > Brayton pumped ther...

Brayton pumped thermal energy storage : Optimal dispatchment in multi-energy districts

Ghilardi, A. (författare)
University of Pisa, Italy
Frate, G. F. (författare)
University of Pisa, Italy
Kyprianidis, Konstantinos (författare)
Mälardalens universitet,Framtidens energi
visa fler...
Tucci, M. (författare)
University of Pisa, Italy
Ferrari, L. (författare)
University of Pisa, Italy
visa färre...
 (creator_code:org_t)
Elsevier, 2024
2024
Engelska.
Ingår i: Energy Conversion and Management. - : Elsevier. - 0196-8904 .- 1879-2227. ; 314
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Energy storage systems play a crucial role in supporting the integration of renewable energy sources. In this framework, Brayton Pumped Thermal Energy Storage is an emerging technology thanks to many positive features, including geographical and raw materials independence, long lifetime, and peculiar sector-coupling capabilities. By storing electric energy as thermal exergy, this technology offers the flexibility to discharge energy directly for heating or cooling applications or convert it back into electricity as needed by the grid. This dual functionality fits well with the multi-energy intrinsic nature of urban districts in which electrical and thermal energy carriers are involved. This paper aims then to evaluate the potential economic benefit due to the usage of a Brayton based Pumped Thermal Energy Storage as multi-energy device instead of a solely electric-to-electric. An urban district with thermal and electric requirements is used as a case study to investigate the techno-economic performance of the mentioned storage capacity when coupled to photo-voltaic plants to simulate deep-decarbonization scenarios. The system day-ahead optimization, performed through a Mixed Integer Linear Programming approach, aims to minimize the operational cost computed over a 24-h horizon. The results highlight that operational yearly cost savings are 5–10 % when using the multi-energy storage functionalities compared to the standard electric-to-electric operation. Despite the cost reduction, allowing only direct heating causes unavoidable thermal curtailment losses in the 6–10 % range. However, these losses can be reduced to 3 % by introducing the additional direct cooling functionality, bringing the best performances from the economic and thermodynamic standpoints.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)

Nyckelord

Mixed integer linear programming
Multi-energy storage
Pumped thermal energy storage
Sector-coupling
Cost reduction
Electric discharges
Electric energy storage
Electric load dispatching
Heat storage
Integer programming
Renewable energy
Brayton
Integer Linear Programming
Mixed integer linear
Multi energy
Thermal
Thermal energy storage
Thermal energy

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Ghilardi, A.
Frate, G. F.
Kyprianidis, Kon ...
Tucci, M.
Ferrari, L.
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Maskinteknik
och Energiteknik
Artiklar i publikationen
Energy Conversio ...
Av lärosätet
Mälardalens universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy