SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Murphy E)
 

Sökning: WFRF:(Murphy E) > (2000-2004) > Unmasking true sign...

Unmasking true signal/tumor information from ProstaScint scans

Lee, Benjamin Y. (författare)
New York University
Dewyngaert, J. Keith (författare)
New York University
Noz, Marilyn E. (författare)
New York University
visa fler...
Maguire Jr., Gerald Q. (författare)
KTH,Mikroelektronik och informationsteknik, IMIT,Computer Communications
Murphy-Walcott, Antoinette (författare)
New York University
Kramer, Elissa L. (författare)
New York University
visa färre...
 (creator_code:org_t)
SPIE - International Society for Optical Engineering, 2004
2004
Engelska.
Ingår i: MEDICAL IMAGING 2004: IMAGE PROCESSING, PTS 1-3. - : SPIE - International Society for Optical Engineering. - 0819452831 ; , s. 1980-1990
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: Improve tumor localization in In-111 ProstaScint SPECT scans through improved reconstruction and identification/removal of non-specific blood pool volumes using simultaneously acquired Tc-99m tagged red blood cell (RBC) SPECT scans. Methods: We chose 30 patients with a history of prostate cancer who had undergone CT/MR and simultaneous Tc-99m RBC/In-111 ProstaScint SPECT scans due to rising PSA. To estimate the impact of reconstruction methods on anatomic definition and artifacts, SPECT volume data sets were reconstructed using ordered set-expectation maximization (OS-EM) with varying numbers of iterations and subsets, and these were compared against each other and against standard filtered back projection (FBP) reconstruction. Non-blood pool bladder activity in the Tc-99m scans was suppressed prior to subtraction from the In-111 scans by using an averaging algorithm within an ellipsoid volume encompassing the bladder. Outside the ellipsoid volume, Tc-99m voxel values were subtracted from the corresponding In-111 voxels after normalization of the data sets based on peak activity within the descending aorta. Results: OS-EM reconstruction using 3 iterations and 45 subsets showed improved representation of anatomy compared with FBP. Bladder suppression reduced artifacts in the prostate bed. The subtraction method reduced the blood pool signal, confirmed visually by superimposition with matched CT/MR scans. Conclusions: OS-EM reconstruction together with bladder suppression and subtraction of the blood pool may help improve the specificity of ProstaScint SPECT interpretation and increase its utility in radiation therapy treatment planning.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

ProstaScint
reconstruction algorithms
artifact elimination
volume fusion
volume subtraction
prostate cancer treatment planning
SRA - ICT
SRA - Informations- och kommunikationsteknik

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy