SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Ranklev Twetman Eva)
 

Search: WFRF:(Ranklev Twetman Eva) > Reproducibility of ...

Reproducibility of in vitro contracture test results in patients tested for malignant hyperthermia susceptibility.

Islander, Gunilla (author)
Lund University,Lunds universitet,Anestesiologi och intensivvård,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Anesthesiology and Intensive Care,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
Ording, H (author)
Bendixen, D (author)
show more...
Ranklev Twetman, Eva (author)
Lund University,Lunds universitet,Anestesiologi och intensivvård,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Anesthesiology and Intensive Care,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
show less...
 (creator_code:org_t)
2002-10-03
2002
English.
In: Acta Anaesthesiologica Scandinavica. - : Wiley. - 0001-5172. ; 46:9, s. 1144-1149
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • BACKGROUND: The in vitro contracture test (IVCT) is the golden standard to diagnose malignant hyperthermia susceptibility (MHS). A high reproducibility is important for a high validity of a test. METHODS: We have therefore analyzed IVCT in 838 patients, investigated in two laboratories. Each halothane and caffeine test was performed in two muscle strips. The test results were analyzed with respect to reproducibility of abnormal outcomes within pairs of tested muscle strips and size of contractures, thresholds and quality criteria. The patients were tested according to the European Malignant Hyperthermia Group protocol (EMHG). To fulfill quality criteria in the EMHG protocol the twitch height should be 10 mN (1 g) or more. For the caffeine test a minimum contracture of 50 mN (5 g) or more at 32 mmol l-1 caffeine could be used as an alternative quality criterion RESULTS: There was better reproducibility with larger contractures. The correlation between size of contractures and fraction of muscle strips with abnormal contractures was 0.77 or larger. Contractures < 5 mN (0.5 g) were reproducible in less than half of the tests. There was no difference in reproducibility or size of contractures between tests fulfillling all quality criteria and those not fulfillling these criteria. CONCLUSIONS: IVCT responses close to cut off limits, i.e. <5 mN (0.5 g) in the EMHG protocol, are less reproducible and must scientifically be considered as less reliable. The clinical cut off limits must remain unchanged for reasons of clinical safety. The outcome of quality measurements does not influence the test results.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Anestesi och intensivvård (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Anesthesiology and Intensive Care (hsv//eng)

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

Find more in SwePub

By the author/editor
Islander, Gunill ...
Ording, H
Bendixen, D
Ranklev Twetman, ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Anesthesiology a ...
Articles in the publication
Acta Anaesthesio ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view