SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Schouenborg J)
 

Sökning: WFRF:(Schouenborg J) > (1995-1999) > Silicon sieve elect...

Silicon sieve electrodes for neural implants - in vitro characterization & in vivo recordings

Wallman, L. (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Levinsson, A. (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups
Schouenborg, J. (författare)
Lund University,Lunds universitet,Neuronano Research Center (NRC),Forskargrupper vid Lunds universitet,Lund University Research Groups
visa fler...
Holmberg, H. (författare)
Lund University,Lunds universitet
Montelius, L. (författare)
Lund University,Lunds universitet,Fasta tillståndets fysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Solid State Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
Danielsen, N. (författare)
Lund University,Lunds universitet,Neurala gränsytor,Forskargrupper vid Lunds universitet,Neural Interfaces,Lund University Research Groups
Laurell, T. (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
1998
1998
Engelska.
Ingår i: Procceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society : Biomedical Engineering Towards the Year 2000 and Beyond - Biomedical Engineering Towards the Year 2000 and Beyond. - 0780351649 ; 20, s. 2225-2228, s. 2225-2228
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • An in vitro model was developed to characterize the electrical properties of silicon microfabricated recording electrodes, using a Cu-wire mimicing a neural signal source. Phosphorous doped electrodes were used to achieve an all silicon device. The model was used to study signal amplitude as a function of distance between the electrode surface and the signal source. Signal crosstalk to neighbouring electrodes on the chips were recorded. The crosstalk was found to be 6 dB using an external reference electrode. Improvements were accomplished with an on chip reference electrode giving an amplitude crosstalk suppression of 20 dB. It was found that the amplitude decreased by a factor of 2 at a distance of 50 μm between the electrode surface and the signal source. Sieve electrodes were also implanted in the rat sciatic nerve and following a 10 week nerve regeneration period the dorsal and ventral (L5) roots in the spinal cord were stimulated. Compound action potentials were recorded via the chip. Lower leg muscle contraction activity was also induced by stimulating the regenerated sciatic nerve via the sieve electrode.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Medicinsk bioteknologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Medical Biotechnology (hsv//eng)

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy