SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:oru-66387"
 

Sökning: onr:"swepub:oai:DiVA.org:oru-66387" > Automating data ana...

  • Titaley, Ivan,1990-Örebro universitet,Institutionen för naturvetenskap och teknik,Department of Chemistry, Oregon State University, Corvallis OR, USA (författare)

Automating data analysis for two-dimensional gas chromatography/time-of-flight mass spectrometry non-targeted analysis of comparative samples

  • Artikel/kapitelEngelska2018

Förlag, utgivningsår, omfång ...

  • Elsevier,2018
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:oru-66387
  • https://urn.kb.se/resolve?urn=urn:nbn:se:oru:diva-66387URI
  • https://doi.org/10.1016/j.chroma.2018.02.016DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Non-targeted analysis of environmental samples, using comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (GC x GC/ToF-MS), poses significant data analysis challenges due to the large number of possible analytes. Non-targeted data analysis of complex mixtures is prone to human bias and is laborious, particularly for comparative environmental samples such as contaminated soil pre- and post-bioremediation. To address this research bottleneck, we developed OCTpy, a Python (TM) script that acts as a data reduction filter to automate GC x GC/ToF-MS data analysis from LECO (R) ChromaTOF (R) software and facilitates selection of analytes of interest based on peak area comparison between comparative samples. We used data from polycyclic aromatic hydrocarbon (PAH) contaminated soil, pre- and post-bioremediation, to assess the effectiveness of OCTpy in facilitating the selection of analytes that have formed or degraded following treatment. Using datasets from the soil extracts pre- and post-bioremediation, OCTpy selected, on average, 18% of the initial suggested analytes generated by the LECO (R) ChromaTOF (R) software Statistical Compare feature. Based on this list, 63-100% of the candidate analytes identified by a highly trained individual were also selected by OCTpy. This process was accomplished in several minutes per sample, whereas manual data analysis took several hours per sample. OCTpy automates the analysis of complex mixtures of comparative samples, reduces the potential for human error during heavy data handling and decreases data analysis time by at least tenfold. (C) 2018 Elsevier B.V. All rights reserved.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Ogba, O. MadukaDepartment of Chemistry, Oregon State University, Corvallis OR, USA; Department of Chemistry, Pomona College, Claremont CA, USA (författare)
  • Chibwe, LeahDepartment of Chemistry, Oregon State University, Corvallis OR, USA (författare)
  • Hoh, EunhaGraduate School of Public Health, San Diego State University, San Diego CA, USA (författare)
  • Cheong, Paul H. -Y.Department of Chemistry, Oregon State University, Corvallis OR, USA (författare)
  • Simonich, Staci L. MasseyDepartment of Chemistry, Oregon State University, Corvallis OR, USA; Department of Environmental and Molecular Toxicology, Oregon State University, Corvallis OR, USA (författare)
  • Örebro universitetInstitutionen för naturvetenskap och teknik (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Journal of Chromatography A: Elsevier1541, s. 57-620021-96731873-3778

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy