Difference in resistance to humidity between commonly used dry powder inhalers : an in vitro study

Janson, Christer (author)
Uppsala universitet,Lungmedicin och allergologi
Lööf, Thomas (author)
AstraZeneca R&D, Molndal, Sweden.
Telg, Gunilla (author)
AstraZeneca Nord Balt, Sodertalje, Sweden.
show more...
Stratelis, Georgios (author)
Uppsala universitet,Lungmedicin och allergologi,AstraZeneca Nord Balt, Sodertalje, Sweden.
Nilsson, Folke (author)
Narhalsan Primary care, Kungshamn, Sweden.
show less...
 (creator_code:org_t)
2016-11-17
2016
English.
In: npj Primary Care Respiratory Medicine. - : Springer Science and Business Media LLC. - 2055-1010. ; 26
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Multi-dose dry powder inhalers (DPIs) are commonly used in asthma and chronic obstructive lung disease (COPD) treatment. A disadvantage is their sensitivity to humidity. In real life, DPIs are periodically exposed to humid conditions, which may affect aerosol characteristics and lung deposition. This study compared DPI aerosol performance after exposure to humidity. Budesonide (BUD) inhalers (Turbuhaler; Novolizer; Easyhaler) and budesonide/formoterol (BUD/FORM) inhalers (Turbuhaler; Spiromax; Easyhaler) were stored in 75% relative humidity (RH) at both ambient temperature and at-0 degrees C. Delivered dose (DD) and fine-particle dose (FPD) were tested in vitro before and after storage. BUD inhalers: Turbuhaler and Novolizer showed only small decreases (<15%) in FPD in 40 degrees C/75% RH, whereas FPD for Easyhaler decreased by >60% (P = 0.01) after 1.5 months of storage. Easyhaler also decreased significantly after 6 months of storage in ambient/75% RH by 25% and 54% for DD and FPD, respectively, whereas only small decreases were seen for Turbuhaler and Novolizer (<15%). BUD/FORM inhalers: Turbuhaler and Spiromax DD were unchanged in 40 degrees C/75% RH, whereas Easyhaler showed a small decrease. FPD (budesonide) decreased for Turbuhaler, Spiromax and Easyhaler by 18%, 10% and 68% (all significant), respectively, at 40 degrees C/75% RH. In ambient/75% RH, DD was unchanged for all inhalers, whereas FPD (budesonide) decreased for Spiromax (7%, P = 0.02) and Easyhaler (34%, (P<0.01)). There are significant differences in device performance after exposure to humid conditions. A clinically relevant decrease of more than half FPD was seen for one of the inhalers, a decrease that may affect patients' clinical outcomes. Prescriber and patient knowledge on device attributes are essential to ensure optimal drug delivery to the lungs.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Lungmedicin och allergi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Respiratory Medicine and Allergy (hsv//eng)

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Find more in SwePub

By the author/editor
Janson, Christer
Lööf, Thomas
Telg, Gunilla
Stratelis, Georg ...
Nilsson, Folke
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Respiratory Medi ...
Articles in the publication
npj Primary Care ...
By the university
Uppsala University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view