SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Thibodeau SN)
 

Sökning: WFRF:(Thibodeau SN) > Measurability and r...

Measurability and reliability of assessments of root length and marginal bone level in cone beam CT and intraoral radiography : a study of adolescents

Al-Okshi, Ayman (författare)
Malmö universitet,Odontologiska fakulteten (OD),Department of Oral Medicine and Radiology, Faculty of Dentistry, Sebha University, Sebha, Libyan Arab Jamahiriya
Paulsson, Liselotte (författare)
Malmö universitet,Odontologiska fakulteten (OD)
Rohlin, Madeleine (författare)
Malmö universitet,Odontologiska fakulteten (OD)
visa fler...
Ebrahim, Eman (författare)
Malmö universitet,Odontologiska fakulteten (OD),Department of Orthodontics, Faculty of Dentistry, Sebha University, Sebha, Libyan Arab Jamahiriya
Lindh, Christina (författare)
Malmö universitet,Odontologiska fakulteten (OD)
visa färre...
 (creator_code:org_t)
British Institute of Radiology, 2019
2019
Engelska.
Ingår i: Dento-Maxillo-Facial Radiology. - : British Institute of Radiology. - 0250-832X .- 1476-542X. ; 48:5, s. 1-9
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objectives: To evaluate measurability and reliability of measurements of root length and marginal bone level in CBCT, periapical (PA) and bitewing (BW) radiographs. Methods: CBCT of both jaws, PA of maxillary incisors and posterior BW radiographs of 10 adolescents (mean age 13.4) were selected. The radiographs comprised part of the baseline examinations of a trial of orthodontic treatment. Six raters assessed measurability and measured root length and marginal bone level. Three raters repeated their assessments. Measurability was expressed as frequency of interpretable sites and reliability as intraclass correlation coefficient (ICC). Results: Measurability was 100 % in CBCT and 95 % in PA of maxillary incisors for root length measurements. For marginal bone level, measurability was 100 % in CBCT, 76 % in PA and 86 % in posterior BW. Mean ICC for interrater reliability for root length measurements in CBCT was 0.88 (range 0.27-0.96 among different teeth) and 0.69 in PA of maxillary incisors. For marginal bone level measurements, mean ICC was 0.4 in CBCT, 0.38 in PA of maxillary incisors and 0.4 in posterior BW. Intrarater reliability varied among methods, root length or marginal bone level and among raters, except for root length measurements in CBCT, which presented high reliability (above 0.8) for all raters. Conclusions: As measurability and reliability were high for root length measurements in CBCT, this may be the method of choice for scientific analyses in orthodontics. For clinical praxis, we recommend PA following the "as low as diagnostically acceptable" principle, as clinical decisions seem to be influenced only when severe root resorption occurs.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Nyckelord

radiography
dental
cone-beam computed tomography
humans
orthodontics
reproducibility of results

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Al-Okshi, Ayman
Paulsson, Liselo ...
Rohlin, Madelein ...
Ebrahim, Eman
Lindh, Christina
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Odontologi
Artiklar i publikationen
Dento-Maxillo-Fa ...
Av lärosätet
Malmö universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy